Sanyo PDG-DHT8000L RS232C Expand - Page 97
CR_TEMPFAIL Command
View all Sanyo PDG-DHT8000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
PDG-DHT8000L Expand Serial Command Functional Specifications 9.11.7 CR_TEMPFAIL Command Command "CR_TEMPFAIL" [CR] Details Get the temperature inside the projector when the abnormal status occurs. It is possible to get the temperatures for more than one sensor all at once if it is applicable. Acceptable "000_%1" [CR] e.g. "_31.5F"[CR] _ indicates a space. When the temperature goes under 0, the first character is "-", not a space, as in "-05.5F". With more than one temperature sensors installed, projector returns the responses for each sensor in a row. e.g. "_31.5F_35.2S" [CR] The first data indicates sensor 1 data, then one space, and sensor 2 data is followed. Last character in each data indicates the sensor's status. In the abnormal temperature F" In the safe level of temperature S" Response %1 Neither in or close to the abnormal temp. ------- "N" The second example above indicates that the temperature detected by sensor 1 is 31.5 which means in the abnormal temperature, and at sensor 2 is 32.5 degrees which is in the safe temperature. When the abnormal temperature status is not occurred the data should be "_00.0S". When the projector is reset, "_00.0S" is set. Every time abnormal temperature status is detected, it renews the data and returns it. It only returns the renewed data of the latest abnormal temperature and the previous data is cleared. Unacceptable "?" [CR] 97/101