Sharp 3800M Operation Manual - Page 42
Drum cartridge life
View all Sharp 3800M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Drum cartridge replacement 6 Using both hands hold the tabs on the new drum cartridge between your thumb and index finger, place the two projections on both ends of the cartridge along the guides, and gently insert the cartridge in the direction indicated by the arrow. 4 7 Carefully remove the sheet of black protective paper from the drum cartridge by pulling the partindicated by the arrow toward you, making sure not to leave any torn pieces of paper in the machine. 8 Gently replace the TD cartridge. To install the TD cartridge, see page 29, TD CARTRIDGE REPLACEMENT. 9 Pressing and holding down both the exposure mode selector key and clear (>) key, close the front cover. Continue to hold down these keys for five seconds (drum initialization processing).The drum replacement required (w) indicator will go out. Drum cartridge life To find out how many more copies can be made before the 20,000 mark is reached, follow the procedure described below. 1 Press and hold down the light ({) and dark (}) keys simultaneously for more than 5 seconds until all the alarm indicators (w, t, s) blink and "- -" appears in the display. 2 Press and hold down the clear (>) key for more than 5 seconds to find out how many more copies can be made. Example: 500 copies can be made before the next drum cartridge replacement. 3 Press the light ({) or dark (}) key. The ready ( ) indicator will light up. 32 SUPPLIES AND USER MAINTENANCE SUK 04 SUPPLIES AND USER MAINTENANCE32LEO.p65 27/03/00, 15:25