Adaptec 29320A-R User Guide - Page 63

Con View SCSI, Controller Settings, Enter, HostRAID, Enabled

Page 63 highlights

Using the SCSISelect Utility to Manage Arrays 4 From the Options menu, select Configure/View SCSI Controller Settings and press Enter. Adaptec SCSISelect(TM) Utility vX.XX 39320A at slot 6, 00:0E:00 Would you like to configure the SCSI controller, configure HostRAID settings, or run the SCSI disk utilities? Select the option and press . Options Configure/View SCSI Controller Settings SCSI Disk Utilities move cursor, accept option, exit (*=default) 5 From the Configuration menu, select HostRAID and press Enter. Adaptec SCSISelect(TM) Utility vX.XX Configuration 39320A at slot 6, 00:0E:00 SCSI Bus Interface Definitions SCSI Controller ID 7........ SCSI Controller Parity Enabled SCSI Controller Termination Automatic Additional Options Boot Device Configuration Press SCSI Device Configuration Press Advanced Configuration Options Press HostRAID Disabled - Reset to SCSI Controller Defaults BIOS Information Interrupt (IRQ) Channel 10 I/O Port Address FC00h, F000h Arrow keys to move cursor, to select option, to exit (*=default) 6 From the HostRAID Pop-Up menu, select Enabled. Note: For information on Configuring SCSI Controller Settings or using SCSI Disk Utilities, see the SCSI controller hardware documentation. 4-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206

4-3
Using the SCSISelect Utility to Manage Arrays
4
From the Options menu, select
Configure/View SCSI
Controller Settings
and press
Enter
.
5
From the Configuration menu, select
HostRAID
and press
Enter
.
6
From the HostRAID Pop-Up menu, select
Enabled
.
Note:
For information on Configuring SCSI Controller
Settings or using SCSI Disk Utilities, see the SCSI
controller hardware documentation.
Adaptec
SCSISelect(TM)
Utility vX.XX
<Arrows> move cursor,
<Enter> accept option,
<Esc> exit (*=default)
Would you like to configure the SCSI controller, configure
HostRAID settings, or run the SCSI disk utilities?
Select
the option and press <Enter>.
39320A at slot 6, 00:0E:00
Options
Configure/View SCSI Controller Settings
SCSI Disk Utilities
Arrow keys to move cursor,
<Enter> to select option,
<Esc> to exit
(
*
=default)
SCSI Bus Interface Definitions
SCSI Controller ID
........................................
7
........
SCSI Controller Parity
....................................
Enabled
SCSI Controller Termination
...........................
Automatic
Additional Options
Boot Device Configuration
..............................
Press <Enter>
SCSI Device Configuration
.............................
Press <Enter>
Advanced Configuration Options
.....................
Press <Enter>
HostRAID
.......................................................
Disabled
<F6> - Reset to SCSI Controller Defaults
Adaptec
SCSISelect(TM)
Utility vX.XX
39320A
at slot 6, 00:0E:00
Configuration
BIOS Information
Interrupt (IRQ) Channel
.................................
10
I/O Port Address
............................................
FC00h, F000h