Cisco WS-C2960S-24TS-S Hardware Installation Guide - Page 85

Power Requirements, Power over Ethernet, Physical Dimensions, Table A-8, Catalyst 2960-48PST-S

Page 85 highlights

Appendix A Technical Specifications Table A-8 Catalyst 2960-48PST-S, 2960-24PC-S, and 2960-24LC-S Switch Specifications Power Requirements AC input voltage DC input voltage for RPS 2300 Power consumption1 100 to 240 VAC (autoranging) 8 to 4 A, 50 to 60 Hz (Catalyst 2960-24PC-S) 3 to 1.5 A, 50 to 60 Hz (Catalyst 2960-24LC-S) 5 to 2 A, 50 to 60 Hz (Catalyst 2960-48PST-S) +12 V @11.25 A, -48 V @ 7.8 A (Catalyst 2960-24PC-S) +12 V @ 8.3 A, -48 V @ 2.7 A (Catalyst 2960-24LC-S) +12 V @ 4 A, -48 V @ 7.8 A (Catalyst 2960-48PST-S) 100 W, 341 BTUs per hour (Catalyst 2960-24PC-S) 51 W, 174 BTUs per hour (Catalyst 2960-24LC-S) 483 W, 1647 BTUs per hour (Catalyst 2960-48PST-S) Power rating 0.470 KVA (Catalyst 2960-24PC-S) 0.175 KVA (Catalyst 2960-24LC-S) 0.5 KVA (Catalyst 2960-48PST-S) Power over Ethernet 15.4 W-per-port maximum, 370-W switch maximum (Catalyst 2960-48PST-S and 2960-24PC-S switches). 15.4 W-per-port maximum, 124-W switch maximum (Catalyst 2960-24LC-S). Physical Dimensions Weight 12 lb (5.44 kg) (Catalyst 2960-24PC-S) 10 lb (4.54 kg) (Catalyst 2960-24LC-S) 12 lb (5.44 kg) (Catalyst 2960-48PST-S) Dimensions (H x W x D) 1.73 x 13 x 17.5 in. (4.39 x 33.02 x 44.45 cm) 1. The power consumption values are for the switch input power. OL-7075-09 Catalyst 2960 Switch Hardware Installation Guide A-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

A-5
Catalyst 2960 Switch Hardware Installation Guide
OL-7075-09
Appendix A
Technical Specifications
Table A-8
Catalyst 2960-48PST-S, 2960-24PC-S, and 2960-24LC-S Switch Specifications
Power Requirements
AC input voltage
100 to 240 VAC (autoranging)
8 to 4 A, 50 to 60 Hz (Catalyst 2960-24PC-S)
3 to 1.5 A, 50 to 60 Hz (Catalyst 2960-24LC-S)
5 to 2 A, 50 to 60 Hz (Catalyst 2960-48PST-S)
DC input voltage for
RPS 2300
+
12 V
@11.25 A, –48 V
@ 7.8 A (Catalyst 2960-24PC-S)
+
12 V
@ 8.3 A, –48 V
@ 2.7 A (Catalyst 2960-24LC-S)
+
12 V
@ 4 A, –48 V
@ 7.8 A (Catalyst 2960-48PST-S)
Power consumption
1
1.
The power consumption values are for the switch input power.
100 W, 341 BTUs per hour (Catalyst 2960-24PC-S)
51 W, 174 BTUs per hour (Catalyst 2960-24LC-S)
483 W, 1647 BTUs per hour (Catalyst 2960-48PST-S)
Power rating
0.470 KVA (Catalyst 2960-24PC-S)
0.175 KVA (Catalyst 2960-24LC-S)
0.5 KVA (Catalyst 2960-48PST-S)
Power over Ethernet
15.4 W-per-port maximum, 370-W switch maximum (Catalyst 2960-48PST-S and 2960-24PC-S
switches). 15.4 W-per-port maximum, 124-W switch maximum (Catalyst 2960-24LC-S).
Physical Dimensions
Weight
12 lb (5.44 kg) (Catalyst 2960-24PC-S)
10 lb (4.54 kg) (Catalyst 2960-24LC-S)
12 lb (5.44 kg) (Catalyst 2960-48PST-S)
Dimensions (H x W x D)
1.73 x 13 x 17.5 in. (4.39 x 33.02 x 44.45 cm)