EPL-N1200 Service Manual Disassembly and Assembly 3.2.2.12 Fusing Unit Removal 1. Open the top cover. Remove the imaging cartridge. Cover the imaging cartridge to protect it from light or place it in a dark area. 2. Remove the main controller board. (Refer to Section 3.2.1.1.) 3. Loosen two CC (M3x8) screws which secure the right cover. 4. Release left and right tabs of the top cover from the printer base unit then remove the top cover. 5. Remove one CC (M3x6) screw on the fusing unit cover and remove the fusing unit cover. 6. Disconnect two connectors for the thermistor and the fusing unit lamp. 7. Remove two CP(O) (M3x6) screws on the fusing unit then remove the fusing unit. Fusing Unit Connector for Thermistor CP(O)(M3X8) CP(O)(M3X8) Connector for Lamp Figure 3-25. Fusing Unit Removal 3.2.2.13 Paper Exit Sensor Removal 1. Remove the fusing unit. (Refer to Section 3.2.2.12.) 2. Remove the paper exit sensor. 3. Disconnect the paper exit sensor from connector of the cable. Connector Paper Exit Sensor Figure 3-26. Paper Exit Sensor Removal Rev. A 3-21