Epson EPL-N1200 Service Manual - Page 140

Table A-5. CN4 Pin Assignments

Page 140 highlights

EPL-N1200 Service Manual Table A-5. CN4 Pin Assignments Appendix A Pin No. Signal Name 27,28,29,30 57,58,59,60 3,4,5,6 41,42,43,44 45 46 47 48 49 50 51 52 53 54 55 56 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 31 32 33 34 35 36 37 38 39 40 VCC VCC GND GND RESET INH CMREQ WRRDY RDREQ WRT RDT TYPB TXD READY RXD NC DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 AB0 AB1 AB2 AB3 AB4 CS RD WR IREQ NMI DREQ DTCT PCLK RST TXD+ TXDRXD+ RXDDTR CTS NC NC LCD SWRD I/O Description - +5 VDC - +5 VDC - Ground - Ground - Not used - Not used - Not used - Not used - Not used - Not used - Not used - Not used - Ground - +5 VDC - Not used - Not used I/O Data bus bit 0 I/O Data bus bit 1 I/O Data bus bit 2 I/O Data bus bit 3 I/O Data bus bit 4 I/O Data bus bit 5 I/O Data bus bit 6 I/O Data bus bit 7 O Address bus bit 0 O Address bus bit 1 O Address bus bit 2 O Address bus bit 3 O Address bus bit 4 O Chip select signal O Read signal O Write signal O Address bus bit 13 O Address bus bit 14 O Address bus bit 11 O Address bus bit 12 O Clock O Reset signal - Not used - Not used - Not used - Not used - Not used - Not used - Not used - Not used - Not used - Not used Rev. A A-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

Table A-5. CN4 Pin Assignments
Pin No.
Signal Name
I/O
Description
27,28,29,30
VCC
+5 VDC
57,58,59,60
VCC
+5 VDC
3,4,5,6
GND
Ground
41,42,43,44
GND
Ground
45
RESET
Not used
46
INH
Not used
47
CMREQ
Not used
48
WRRDY
Not used
49
RDREQ
Not used
50
WRT
Not used
51
RDT
Not used
52
TYPB
Not used
53
TXD
Ground
54
READY
+5 VDC
55
RXD
Not used
56
NC
Not used
7
DB0
I/O
Data bus bit 0
8
DB1
I/O
Data bus bit 1
9
DB2
I/O
Data bus bit 2
10
DB3
I/O
Data bus bit 3
11
DB4
I/O
Data bus bit 4
12
DB5
I/O
Data bus bit 5
13
DB6
I/O
Data bus bit 6
14
DB7
I/O
Data bus bit 7
15
AB0
O
Address bus bit 0
16
AB1
O
Address bus bit 1
17
AB2
O
Address bus bit 2
18
AB3
O
Address bus bit 3
19
AB4
O
Address bus bit 4
20
CS
O
Chip select signal
21
RD
O
Read signal
22
WR
O
Write signal
23
IREQ
O
Address bus bit 13
24
NMI
O
Address bus bit 14
25
DREQ
O
Address bus bit 11
26
DTCT
O
Address bus bit 12
1
PCLK
O
Clock
2
RST
O
Reset signal
31
TXD+
Not used
32
TXD-
Not used
33
RXD+
Not used
34
RXD-
Not used
35
DTR
Not used
36
CTS
Not used
37
NC
Not used
38
NC
Not used
39
LCD
Not used
40
SWRD
Not used
EPL-N1200 Service Manual
Appendix A
Rev. A
A-9