Epson EPL-N1200 Service Manual - Page 107

CCM3X6, Thermistor

Page 107 highlights

EPL-N1200 Service Manual Disassembly and Assembly 3.2.2.15 Thermistor and Thermostat Removal 1. Remove the fusing unit. (Refer to Section 3.2.2.12.) 2. Remove the fusing lamp. (Refer to Section 3.2.2.13.) 3. Take the thermistor cable out of its guide in the fusing unit housing. 4. Remove two CC (M3 × 6) screws on the top surface of the fusing unit, and remove the side covers. 5. Divide the fusing unit into two parts. 6. Remove one CC (M3 × 10) screw then remove the Thermistor. 7. Remove two CS(P) (M3x6) screws then remove the thermostat. CAUTION * Do not touch the glass surface of the lamp with your bare hands. * The thermistor and thermostat must be attached at the fusing roller. * The connector for the thermistor must be inserted firmly. CC(M3X6) Figure 3-29. Fusing Unit Disassembly CC(M3X10) CS(P)(M3X6) Thermistor Thermostat Figure 3-30. Thermistor and Thermostat Removal Rev. A 3-23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

3.2.2.15
Thermistor and Thermostat Removal
1.
Remove the fusing unit.
(Refer to Section 3.2.2.12.)
2.
Remove the fusing lamp. (Refer to Section 3.2.2.13.)
3.
Take the thermistor cable out of
its guide in the fusing unit housing.
4.
Remove two CC (M3
×
6) screws on the top surface of the fusing unit, and remove the side
covers.
5.
Divide the fusing unit into two parts.
6.
Remove one CC (M3
×
10) screw then remove the Thermistor.
7.
Remove two CS(P) (M3x6) screws then remove the thermostat.
CC(M3X6)
Figure 3-29. Fusing Unit Disassembly
Thermistor
CC(M3X10)
Thermostat
CS(P)(M3X6)
Figure 3-30. Thermistor and Thermostat Removal
EPL-N1200 Service Manual
Disassembly and Assembly
Rev. A
3-23