Epson Equity 486DX2/50 PLUS User Manual - Page 190
Modifying the Device List
View all Epson Equity 486DX2/50 PLUS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 190 highlights
Modifying the Device List If an installed device is missing from the Device List, you can add it to the list for testing. At the following prompt, select N. DEVICE LIST is correct ? (Y/N) You see this menu: 1 - Add device 2 - Delete device 0 - Finish modification To add a device to the list, select 1. The program displays a list of other devices that are not currently included in the Device List. You see a menu similar to this: Additional DEVICE LIST 4 - Monochrome display adapter and CRT 7 - Math coprocessor 12 - Alternate serial port 21 - Alternate parallel port 81 - Parallel port (on video adapter) 0 - Exit to DEVICE LIST Highlight the item you wish to add and press IEnter You can add as many devices as necessary. When the Device List is complete, select 0 (Exit). To remove a device from the list, select 2 (Delete device). The screen displays the current Device List. Select the item you wish to delete. You can delete as many devices as necessary. When the Device List is correct, select 0. The screen displays the modified Device List for a final check. If the list is correct, select 0 (Finish modification). Performing System Diagnostics C-5