Gateway E-9510T Gateway 9510 Server User Guide - Page 148

Check Rebuild Rate, Exit Web Console, Reclaiming Hot Spare Disks, Reconfiguring Existing Arrays

Page 148 highlights

Launching the Web Console Check Rebuild Rate Select the correct adapter from the Adapter box. Select Rebuild Rate from the Adapter menu. If there is more than one adapter in the system, click each adapter and check the rebuild rate. The rebuild rate is not affected when you clear the configuration. Exit Web Console Select Exit from the Configuration menu to quit the Web Console. Reclaiming Hot Spare Disks To reclaim hot spare disks during normal operation, select the drive and select Remove Hot Spare from the right pane. The Web Console changes the state of the selected drives to the READY state. Reconfiguring Existing Arrays This section provides instructions for adding and removing physical drives from existing arrays. Adding a Physical Drive to an Existing Array To add a physical drive to an array: 1 Go to the Config View screen. 2 Highlight the logical drive and select properties from the left pane. Select the drive to add from the Add Physical Drive pane. Removing a Physical Drive from an Array To selectively remove hard drives from an existing array: 1 Go to the Config View screen. 2 Highlight the logical drive you want to remove, then select Delete from the left pane. www.gateway.com 143

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222

143
www.gateway.com
Launching the Web Console
Check Rebuild Rate
Select the correct adapter from the
Adapter
box. Select
Rebuild Rate
from the
Adapter
menu.
If there is more than one adapter in the system, click each adapter and check the rebuild
rate. The rebuild rate is not affected when you clear the configuration.
Exit Web Console
Select
Exit
from the
Configuration
menu to quit the Web Console.
Reclaiming Hot Spare Disks
To reclaim hot spare disks during normal operation, select the drive and select
Remove
Hot Spare
from the right pane. The Web Console changes the state of the selected drives
to the
READY
state.
Reconfiguring Existing Arrays
This section provides instructions for adding and removing physical drives from existing
arrays.
Adding a Physical Drive to an Existing Array
To add a physical drive to an array:
1
Go to the
Config View
screen.
2
Highlight the logical drive and select properties from the left pane. Select the drive
to add from the
Add Physical Drive
pane.
Removing a Physical Drive from an Array
To selectively remove hard drives from an existing array:
1
Go to the
Config View
screen.
2
Highlight the logical drive you want to remove, then select
Delete
from the left pane.