HP Cisco Nexus 5000 Cisco MDS 9000 Family Fabric Manager Quick Configuration G - Page 80

Domain Manager, Configuration, static., Persistent Setup, Enable, Apply Changes, Persistent Fcids

Page 80 highlights

Appendix C Configuring Static Domain IDs and Persistent FC IDs Send documentation comments to [email protected] In the following procedure, the existing VSAN has a switch C-186 with a domain ID of 209. In Fabric Manager, the VSAN is statically configured and a persistent FC ID is enabled. This procedure does not alter the running domain ID. To configure a static domain ID for an existing VSAN and enable a persistent FC ID for the same VSAN using Fabric Manager, follow these steps: Step 1 Step 2 Step 3 Step 4 Step 5 In the Logical Domains pane, expand the VSAN to be modified and then choose Domain Manager. See Figure C-1. Click the Configuration tab. Enter the domain ID that is in the Running DomainID (in Figure C-1, it is 209) field in the Config Domain Id field. Change the Config Domain IdType field to static. Click the green Apply Changes... icon . Figure C-1 Enabling Static Domain ID Step 6 Step 7 Step 8 Click the Persistent Setup tab. Check the Enable check box. Click Apply Changes. At this point, the domain ID has been statically set and FC IDs will remain persistent across reboots for VSAN 3000 on the switch C-186. The persistent FC ID database can be viewed in the Persistent Fcids tab. Cisco MDS 9000 Family Fabric Manager Quick Configuration Guide C-2 OL-7765-06

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Send documentation comments to [email protected]
C-2
Cisco MDS 9000 Family Fabric Manager Quick Configuration Guide
OL-7765-06
Appendix C
Configuring Static Domain IDs and Persistent FC IDs
In the following procedure, the existing VSAN has a switch C-186 with a domain ID of 209. In Fabric
Manager, the VSAN is statically configured and a persistent FC ID is enabled. This procedure does not
alter the running domain ID.
To configure a static domain ID for an existing VSAN and enable a persistent FC ID for the same VSAN
using Fabric Manager, follow these steps:
Step 1
In the Logical Domains pane, expand the VSAN to be modified and then choose
Domain Manager
. See
Figure C-1
.
Step 2
Click the
Configuration
tab.
Step 3
Enter the domain ID that is in the Running DomainID (in
Figure C-1
, it is 209) field in the Config
Domain Id field.
Step 4
Change the Config Domain IdType field to
static.
Step 5
Click the green
Apply Changes...
icon
Figure C-1
Enabling Static Domain ID
Step 6
Click the
Persistent Setup
tab.
Step 7
Check the
Enable
check box.
Step 8
Click
Apply Changes
.
At this point, the domain ID has been statically set and FC IDs will remain persistent across reboots for
VSAN 3000 on the switch C-186. The persistent FC ID database can be viewed in the
Persistent Fcids
tab.