HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 16
IPMI System Event Log SEL is full. Probable Cause: IPMI SEL full. Recommended
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Event ID Event Severity Event Description 5084 Error Error extracting sal_b from rom. Probable Cause: ROM Corrupt or unreadable. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 250. WBEM ProviderName: FPL_IndicationProvider 5085 Error Scratch RAM bad. Probable Cause: Bad or corrupt Scratch RAM. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 251. WBEM ProviderName: FPL_IndicationProvider 5087 Warning IPMI System Event Log (SEL) is full. Probable Cause: IPMI SEL full. Recommended Action: Clear SEL through BMC or MP. WBEM EventID: 252. WBEM ProviderName: FPL_IndicationProvider 5091 Warning Slave wakeup before vector registered. Probable Cause: No wakeup vector registered for processor. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 253. WBEM ProviderName: FPL_IndicationProvider 5092 Warning CPU failed rendezvous handler. Probable Cause: SFW is unable to determine the FSB speed. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 254. WBEM ProviderName: FPL_IndicationProvider 5098 Error Error building SMBIOS Tables. Probable Cause: SFW failed to build the SMBIOS tables. Recommended Action: If SMBIOS is preventing functionality, reboot. If problem persists contact your HP representative for support. WBEM EventID: 255. WBEM ProviderName: FPL_IndicationProvider 5100 Error Trap nest limit exceeded. Probable Cause: The trap nesting limit has been exceeded. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 256. WBEM ProviderName: FPL_IndicationProvider 5101 Error Trap not serviced. Probable Cause: A invalid trap has been requested or a trap has not been installed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 257. WBEM ProviderName: FPL_IndicationProvider 5102 Error Trap taken. Probable Cause: A trap has been taken Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 258. WBEM ProviderName: FPL_IndicationProvider 5103 Warning Uncleared interrupt. Probable Cause: At least one interrupt was not cleared. Recommended Action: No action is required. WBEM EventID: 259. WBEM ProviderName: FPL_IndicationProvider 5104 Error Unexpected external interrupt. Probable Cause: An unexpected external interrupt has occurred. Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 260. WBEM ProviderName: FPL_IndicationProvider 5105 Error Interrupt before redirection table set up. Probable Cause: An interrupt has occurred before setting up the Interrupt Vector Table. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 261. WBEM ProviderName: FPL_IndicationProvider 5106 Error CPU unexpected MCA. Probable Cause: Unexpected MCA Recommended Action: Reboot or update System FW. If problem persists contact your HP representative for support. WBEM EventID: 262. WBEM ProviderName: FPL_IndicationProvider 16 WBEM Provider Event Tables