HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 33
Cause: Out of resources. Internal EFI error. Recommended Action: Reboot system.
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Event ID Event Severity Event Description 5722 Warning EFI unable to read current speedy boot settings. Probable Cause: BMC not functioning properly. Recommended Action: Reset the BMC. Contact your HP representative to check the BMC. WBEM EventID: 470. WBEM ProviderName: FPL_IndicationProvider 5723 Error Unpermitted SAL callback attempted. Probable Cause: Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 471. WBEM ProviderName: FPL_IndicationProvider 5724 Warning EFI unable to determine frequency base of the CPU interval timer. Probable Cause: Invalid timer ratio. Recommended Action: Reset system. WBEM EventID: 472. WBEM ProviderName: FPL_IndicationProvider 5725 Warning EFI system events already initialized. Probable Cause: Multiple attempts to initialize system events, EFI internal error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 473. WBEM ProviderName: FPL_IndicationProvider 5726 Warning Unable to create internal virtualization event while initializing IPMI events. Probable Cause: Out of resources. Internal EFI error. Recommended Action: Reboot system. Upgrade system firmware. WBEM EventID: 474. WBEM ProviderName: FPL_IndicationProvider 5728 Error There was an error creating or initializing the FPGA node in firmware. Probable Cause: Unable to properly initialize a system firmware node Recommended Action: Check for other errors in the system first. Invalidate NVM and retry to boot. Get the latest firmware release. WBEM EventID: 476. WBEM ProviderName: FPL_IndicationProvider 5729 Error Error creating the pdh ioconfig node or attaching the service to it. Probable Cause: This is likely to be a symptom of an earlier problem, or the system is out of malloc space. Recommended Action: Contact system firmware team. WBEM EventID: 1009. WBEM ProviderName: FPL_IndicationProvider 5730 Error Error encountered setting up the dillon_pdh node or service. Probable Cause: This is usually a symptom of an earlier problem. Check to be sure the pdh node was initialized into the tree correctly. WBEM EventID: 1010. WBEM ProviderName: FPL_IndicationProvider 5731 Error The PDH component encountered an error dealing with a property on a node. Probable Cause: This is usually due to a memory allocation problem. Verify that sram is usable and there is memory available. WBEM EventID: 2459. WBEM ProviderName: FPL_IndicationProvider 5732 Error Error creating the acpi_hw node. Probable Cause: May be out of malloc space or a previous tree error prevented this from being successful. Check for earlier errors. WBEM EventID: 2460. WBEM ProviderName: FPL_IndicationProvider 5733 Error Error encountered creating or initializing the ipmi node. Probable Cause: Possibly out of memory or an earlier error left the tree in an unusable state. WBEM EventID: 2461. WBEM ProviderName: FPL_IndicationProvider 5734 Error some processors not compatible. Probable Cause: Installed processors are not of compatible models or families Recommended Action: Replace processors with compatible ones if all processors are to be used. WBEM EventID: 481. WBEM ProviderName: FPL_IndicationProvider 5735 Error caches sizes are inconsistent. Probable Cause: Processors with different cache sizes are installed in the system. Recommended Action: Replace processors with compatible ones if all processors are to be used. WBEM EventID: 482. WBEM ProviderName: FPL_IndicationProvider 5737 Warning selecting new monarch. Probable Cause: The monarch processor was not the lowest stepping processor installed within the cell. Recommended Action: No action is required. FW takes action automatically. To avoid this event, be sure that the monarch processor is the lowest stepping of processor in the system. WBEM EventID: 484. WBEM ProviderName: FPL_IndicationProvider Platform Events 33