HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 37
Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Event ID Event Severity Event Description 5793 Error An unexpected or invalid value was read from a crossbar remote route table. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PDCheck the XBC chips seating reset the system replace either cells/system backplane WBEM EventID: 527. WBEM ProviderName: FPL_IndicationProvider 5794 Error Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible bad link, crossbar, or cell connection. Recommended Action: Check crossbar and link specified in the event data. Reset cell. WBEM EventID: 528. WBEM ProviderName: FPL_IndicationProvider 5795 Warning memory DIMM quad mis-match. Probable Cause: The user installed a mismatched quad of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in quads of DIMMs that are the same size and DRAM width. WBEM EventID: 529. WBEM ProviderName: FPL_IndicationProvider 5796 Warning Firmware detected excessive errors on the DIMM. Probable Cause: Firmware detected excessive errors on the DIMM / Replace the specified DIMM WBEM EventID: 530. WBEM ProviderName: FPL_IndicationProvider 5797 Error The OE (output enable) bit was not set for a XBC port. Probable Cause: Possible firmware or link error. Recommended Action: Check XBC and port specified by event data. WBEM EventID: 531. WBEM ProviderName: FPL_IndicationProvider 5798 Error An error occurred while trying to read the PORT_STATUS CSR for a XBC port. Probable Cause: Possible bad connection between cell and backplane. Recommended Action: Check for hardware errors. Reset cell. WBEM EventID: 532. WBEM ProviderName: FPL_IndicationProvider 5799 Error A XBC port was unexpectedly found to be landmined. Probable Cause: No action required. WBEM EventID: 533. WBEM ProviderName: FPL_IndicationProvider 5800 Error CPUs running at different speeds were detected during rendezvous. Probable Cause: Reconfigure the PD so that all cells have processors running at the same speed. WBEM EventID: 1016. WBEM ProviderName: FPL_IndicationProvider 5802 Error The link between the local CC and the local XBC is unexpectedly not initialized. Probable Cause: An error initializing fabric Recommended Action: A previously reported event may provide exact detailsReboot, if failure persists, then either replace the CC chip or the system backplane. WBEM EventID: 535. WBEM ProviderName: FPL_IndicationProvider 5803 Error An invalid XBC number was given. Probable Cause: Firmware error Recommended Action: Reset cell WBEM EventID: 536. WBEM ProviderName: FPL_IndicationProvider 5804 Error An invalid XBC port number was given. Probable Cause: Firmware error Recommended Action: Reset cell WBEM EventID: 537. WBEM ProviderName: FPL_IndicationProvider 5805 Warning A bad parameter was passed to the LED function in the utilities component. Probable Cause: Contact FW engineering. This is a bug. WBEM EventID: 2464. WBEM ProviderName: FPL_IndicationProvider 5806 Error An unexpected neighbor type was read from a XBC PORT_NEIGHBOR_INFO CSR. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. WBEM EventID: 539. WBEM ProviderName: FPL_IndicationProvider 5807 Error A given XBC port is not a valid XBC-CC port. Probable Cause: Firmware error. Recommended Action: Reset cell WBEM EventID: 540. WBEM ProviderName: FPL_IndicationProvider 5808 Error A XBC port was unexpectedly found to be an invalid XBC-XBC port. Probable Cause: Firmware error. Recommended Action: Reset cell. WBEM EventID: 541. WBEM ProviderName: FPL_IndicationProvider Platform Events 37