HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 22

OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT

Page 22 highlights

Event ID Event Severity Event Description 5252 Warning The DIMM Loading Order check was bypassed. Probable Cause: Control bit to skip DIMM loading order check is set. Recommended Action: Clear NVM Recommended Action: Update PDC Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 334. WBEM ProviderName: FPL_IndicationProvider 5253 Warning Looping on destructive memory tests. Probable Cause: Control bit to loop on destructive memory test is set. Recommended Action: Clear NVM Recommended Action: Update PDC Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 335. WBEM ProviderName: FPL_IndicationProvider 5255 Warning DIMM Set Check has been skipped. Probable Cause: Control bit to skip DIMM set check is set. Recommended Action: Clear NVM Recommended Action: Update PDC Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 336. WBEM ProviderName: FPL_IndicationProvider 5256 Warning Serial Presence Detect (SPD) has been skipped. Probable Cause: Control bit to skip DIMM SPD check is set. Recommended Action: Clear NVM Recommended Action: Update PDC Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 337. WBEM ProviderName: FPL_IndicationProvider 5257 Warning An Alternate Memory Config has been loaded into the system. Probable Cause: Control bit to use an alternate memory config are set. Recommended Action: Clear NVM Update SFW Contact HP support to troubleshoot the problem WBEM EventID: 338. WBEM ProviderName: FPL_IndicationProvider 5260 Warning OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT vector. Recommended Action: No action is required. The OS has failed to register the vector or has chosen not to. WBEM EventID: 340. WBEM ProviderName: FPL_IndicationProvider 5263 Warning OS MCA address not registered. Probable Cause: The OS has not registered an OS_MCA vector. Recommended Action: None, the OS has failed to register the vector or has chosen not to. WBEM EventID: 341. WBEM ProviderName: FPL_IndicationProvider 5264 Warning OS MCA did not correct the Machine Check. Probable Cause: Uncorrected Machine Check. Recommended Action: Analyze cause of Machine Check using diagnostic and EFI tools. WBEM EventID: 342. WBEM ProviderName: FPL_IndicationProvider 5266 Error Found bad miscellaneous register. Probable Cause: A PDH register has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 343. WBEM ProviderName: FPL_IndicationProvider 5268 Warning SAL_CHECK failed for an unknown reason. Probable Cause: The handler for SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 344. WBEM ProviderName: FPL_IndicationProvider 5270 Warning SAL_INIT failed for an unknown reason. Probable Cause: The handler for SAL_INIT has failed for an unknown reason. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 345. WBEM ProviderName: FPL_IndicationProvider 5278 Warning Unspecified memory interleave error. Probable Cause: FW encountered a fatal interleaving error. Recommended Action: Update SFW Recommended Action: Contact HP support to troubleshoot the problem WBEM EventID: 346. WBEM ProviderName: FPL_IndicationProvider 5279 Error Unexpected return to SAL_CHECK. Probable Cause: Unexpected return to SAL_CHECK. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 347. WBEM ProviderName: FPL_IndicationProvider 5280 Error Unexpected return to SAL_INIT. Probable Cause: SAL_INIT has been unexpectedly returned to. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 348. WBEM ProviderName: FPL_IndicationProvider 22 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
The DIMM Loading Order check was bypassed. Probable Cause: Control bit to skip
DIMM loading order check is set. Recommended Action: Clear NVM Recommended
Action: Update PDC Recommended Action: Contact HP support to troubleshoot the
problem WBEM EventID: 334. WBEM ProviderName: FPL_IndicationProvider
Warning
5252
Looping on destructive memory tests. Probable Cause: Control bit to loop on
destructive memory test is set. Recommended Action: Clear NVM Recommended
Action: Update PDC Recommended Action: Contact HP support to troubleshoot the
problem WBEM EventID: 335. WBEM ProviderName: FPL_IndicationProvider
Warning
5253
DIMM Set Check has been skipped. Probable Cause: Control bit to skip DIMM set
check is set. Recommended Action: Clear NVM Recommended Action: Update PDC
Recommended Action: Contact HP support to troubleshoot the problem WBEM
EventID: 336. WBEM ProviderName: FPL_IndicationProvider
Warning
5255
Serial Presence Detect (SPD) has been skipped. Probable Cause: Control bit to skip
DIMM SPD check is set. Recommended Action: Clear NVM Recommended Action:
Update PDC Recommended Action: Contact HP support to troubleshoot the problem
WBEM EventID: 337. WBEM ProviderName: FPL_IndicationProvider
Warning
5256
An Alternate Memory Config has been loaded into the system. Probable Cause:
Control bit to use an alternate memory config are set. Recommended Action: Clear
NVM Update SFW Contact HP support to troubleshoot the problem WBEM EventID:
338. WBEM ProviderName: FPL_IndicationProvider
Warning
5257
OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT
vector. Recommended Action: No action is required. The OS has failed to register
the vector or has chosen not to. WBEM EventID: 340. WBEM ProviderName:
FPL_IndicationProvider
Warning
5260
OS MCA address not registered. Probable Cause: The OS has not registered an
OS_MCA vector. Recommended Action: None, the OS has failed to register the vector
or has chosen not to. WBEM EventID: 341. WBEM ProviderName:
FPL_IndicationProvider
Warning
5263
OS MCA did not correct the Machine Check. Probable Cause: Uncorrected Machine
Check. Recommended Action: Analyze cause of Machine Check using diagnostic
and EFI tools. WBEM EventID: 342. WBEM ProviderName: FPL_IndicationProvider
Warning
5264
Found bad miscellaneous register. Probable Cause: A PDH register has failed.
Recommended Action: Reboot if necessary, if problem persists contact your HP
representative for support. WBEM EventID: 343. WBEM ProviderName:
FPL_IndicationProvider
Error
5266
SAL_CHECK failed for an unknown reason. Probable Cause: The handler for
SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if
necessary, if problem persists contact your HP representative for support. WBEM
EventID: 344. WBEM ProviderName: FPL_IndicationProvider
Warning
5268
SAL_INIT failed for an unknown reason. Probable Cause: The handler for SAL_INIT
has failed for an unknown reason. Recommended Action: Reboot if necessary, if
problem persists contact your HP representative for support. WBEM EventID: 345.
WBEM ProviderName: FPL_IndicationProvider
Warning
5270
Unspecified memory interleave error. Probable Cause: FW encountered a fatal
interleaving error. Recommended Action: Update SFW Recommended Action: Contact
HP support to troubleshoot the problem WBEM EventID: 346. WBEM ProviderName:
FPL_IndicationProvider
Warning
5278
Unexpected return to SAL_CHECK. Probable Cause: Unexpected return to
SAL_CHECK. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 347. WBEM ProviderName:
FPL_IndicationProvider
Error
5279
Unexpected return to SAL_INIT. Probable Cause: SAL_INIT has been unexpectedly
returned to. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. WBEM EventID: 348. WBEM ProviderName:
FPL_IndicationProvider
Error
5280
22