HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 30
MC: I/O error log/clear error. Probable Cause: SFW's Machine Check Handler was
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Event ID Event Severity Event Description 5606 Warning PAL B execution rom warning. Probable Cause: PAL_B_ROM has generated a warning. Recommended Action: Reboot, update SFW if necessary, if problem persists contact your HP representative for support. WBEM EventID: 588. WBEM ProviderName: FPL_IndicationProvider 5607 Error An error was encountered when firmware tried to update the Group B Profile. Probable Cause: Utilities may be unavailable to update the profiles. Check the connections are reset. WBEM EventID: 1030. WBEM ProviderName: FPL_IndicationProvider 5617 Warning PCI parity error detected. Probable Cause: I/O bus parity error. Recommended Action: Consult the error logs for additional information. Determine and replace the failed I/O device. WBEM EventID: 430. WBEM ProviderName: FPL_IndicationProvider 5618 Warning PCI system error detected. Probable Cause: I/O device failure. Recommended Action: Consult the error logs for additional information. Determine and replace the failed I/O device. WBEM EventID: 431. WBEM ProviderName: FPL_IndicationProvider 5619 Warning I/O host bridge is deconfigured. Probable Cause: See earlier error event. Recommended Action: See earlier error event. WBEM EventID: 432. WBEM ProviderName: FPL_IndicationProvider 5621 Error Firmware was unable to publish the Partition Profile. Probable Cause: Utilities may be unavailable to update the profiles. Check the connections are reset. WBEM EventID: 1008. WBEM ProviderName: FPL_IndicationProvider 5622 Error The reporting cell is not configured to be in a PD. Probable Cause: Run parmgr to configure the cell into a PD and reset the PD or add the cell. WBEM EventID: 434. WBEM ProviderName: FPL_IndicationProvider 5623 Warning DIMM thermal loading order warning. Probable Cause: The current DIMM loading order does not follow the guidelines in the user manual Recommended Action: Rearrange the DIMMs to follow the loading order specified in the Maintenance and Operation Manual WBEM EventID: 435. WBEM ProviderName: FPL_IndicationProvider 5626 Error The PD cannot boot, a majority of cells did not arrive at Rendezvous. Probable Cause: PD Rendezvous Boot Rules: If greater than 50% of the assigned cells are rendezvoused, we will boot. If less than 50% of the assigned cells are rendezvoused, don't boot. If exactly 50% of the assigned cells are rendezvoused, including all of the preferred core cells, we will boot. If exactly 50% have rendezvoused, and there is a specified preferred core cell not rendezvoused, don't boot. If exactly 50% have rendezvoused, and there are no preferred core cells, don't boot. If any of the above apply in preventing the boot. Reconfigure the PD and reboot. WBEM EventID: 437. WBEM ProviderName: FPL_IndicationProvider 5638 Warning INIT: Monarch failed in slave rendezvous. Probable Cause: A processor has failed rendezvous. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 439. WBEM ProviderName: FPL_IndicationProvider 5646 Warning MC: I/O error log/clear error. Probable Cause: SFW's Machine Check Handler was unable to log or clear I/O error registers. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 440. WBEM ProviderName: FPL_IndicationProvider 5655 Warning MC: MCA to BERR escalation not supported by PAL. Probable Cause: Cannot escalate an MCA to BERR. Recommended Action: Analyze Machine Check Logs using diagnostic tools and EFI tools. WBEM EventID: 441. WBEM ProviderName: FPL_IndicationProvider 5656 Warning MC: MCA to BINIT escalation not supported by PAL. Probable Cause: Cannot escalate an MCA to BINIT. Recommended Action: Analyze Machine Check Logs using diagnostic tools and EFI tools. WBEM EventID: 442. WBEM ProviderName: FPL_IndicationProvider 30 WBEM Provider Event Tables