HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 19

DIMM number not found in DMT Table. Probable Cause:. Probable internal FW error - user manual

Page 19 highlights

Event ID Event Severity Event Description 5155 Error Error in temporary mdt area. Probable Cause: The memory area where the MDT is supposed to be built has an error in it, so the MDT cannot be built there. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProvider 5156 Error Failed to find lmmio entry in mdt. Probable Cause: The MDT table is bad because it did not have an LMMIO entry in it. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 294. WBEM ProviderName: FPL_IndicationProvider 5157 Error Memory page zero bad. Probable Cause: Memory page 0 was slated for deallocation in the PDT. Recommended Action: FW is written such that this event should never be generated. If the user sees this event, please contact HP support. WBEM EventID: 295. WBEM ProviderName: FPL_IndicationProvider 5158 Error Failed to find space in mdt. Probable Cause: FW requested an entry in the MDT, and there wasn't a large enough chunk of contiguous memory for the requested size. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 296. WBEM ProviderName: FPL_IndicationProvider 5159 Warning Media failure: info was not retrieved/logged. Probable Cause: The Error handler has failed to retrieve or log data due to a media failure. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 297. WBEM ProviderName: FPL_IndicationProvider 5160 Warning Bus interface register test failed. Probable Cause: The CEC failed the register test. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 298. WBEM ProviderName: FPL_IndicationProvider 5161 Warning Memory ECC normal write/read test failed. Probable Cause: The DIMM that maps to cache line 0 is in a chipspare condition Recommended Action: Contact HP support WBEM EventID: 299. WBEM ProviderName: FPL_IndicationProvider 5171 Warning DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM is not loaded in order to allow for proper operation of the DIMM specified in the physical location. Recommended Action: Refer to the user's manual for Memory loading instructions. WBEM EventID: 300. WBEM ProviderName: FPL_IndicationProvider 5172 Warning DIMM SPD checksum failed. Probable Cause: The DIMMs SPD EEPROM got corrupted. Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 301. WBEM ProviderName: FPL_IndicationProvider 5173 Warning DIMM SPD fatal error. Probable Cause: Detection of SPD error type - various types Recommended Action: Reseat or replace the DIMM. If problem persists, contact HP Support personnel to troubleshoot the problem WBEM EventID: 302. WBEM ProviderName: FPL_IndicationProvider 5174 Warning Unsupported memory DIMM type. Probable Cause: A DIMM with an invalid DIMM type was found Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 303. WBEM ProviderName: FPL_IndicationProvider 5175 Warning The DIMM type of this DIMM doesn't match with others in the DIMM group. Probable Cause: The DIMMs in the rank do not have the same DIMM type Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 304. WBEM ProviderName: FPL_IndicationProvider 5176 Warning The DIMM type table is full. New DIMM type cannot be added. Probable Cause: Too many different types of DIMMs in system Recommended Action: Reduce the number of different types of DIMMs in the system. WBEM EventID: 305. WBEM ProviderName: FPL_IndicationProvider 5179 Warning DIMM number not found in DMT Table. Probable Cause:. Probable internal FW error Recommended Action: Reload System Firmware Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 306. WBEM ProviderName: FPL_IndicationProvider Platform Events 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Error in temporary mdt area. Probable Cause: The memory area where the MDT is
supposed to be built has an error in it, so the MDT cannot be built there.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProvider
Error
5155
Failed to find lmmio entry in mdt. Probable Cause: The MDT table is bad because it
did not have an LMMIO entry in it. Recommended Action: Reboot, if problem persists
contact your HP representative for support. WBEM EventID: 294. WBEM
ProviderName: FPL_IndicationProvider
Error
5156
Memory page zero bad. Probable Cause: Memory page 0 was slated for deallocation
in the PDT. Recommended Action: FW is written such that this event should never
be generated. If the user sees this event, please contact HP support. WBEM EventID:
295. WBEM ProviderName: FPL_IndicationProvider
Error
5157
Failed to find space in mdt. Probable Cause: FW requested an entry in the MDT, and
there wasn't a large enough chunk of contiguous memory for the requested size.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 296. WBEM ProviderName: FPL_IndicationProvider
Error
5158
Media failure: info was not retrieved/logged. Probable Cause: The Error handler has
failed to retrieve or log data due to a media failure. Recommended Action: Reboot
if necessary, if problem persists contact your HP representative for support. WBEM
EventID: 297. WBEM ProviderName: FPL_IndicationProvider
Warning
5159
Bus interface register test failed. Probable Cause: The CEC failed the register test.
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 298. WBEM ProviderName: FPL_IndicationProvider
Warning
5160
Memory ECC normal write/read test failed. Probable Cause: The DIMM that maps
to cache line 0 is in a chipspare condition Recommended Action: Contact HP support
WBEM EventID: 299. WBEM ProviderName: FPL_IndicationProvider
Warning
5161
DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM
is not loaded in order to allow for proper operation of the DIMM specified in the
physical location. Recommended Action: Refer to the user's manual for Memory
loading instructions. WBEM EventID: 300. WBEM ProviderName:
FPL_IndicationProvider
Warning
5171
DIMM SPD checksum failed. Probable Cause: The DIMMs SPD EEPROM got
corrupted. Recommended Action: Contact HP Support personnel to troubleshoot
the problem WBEM EventID: 301. WBEM ProviderName: FPL_IndicationProvider
Warning
5172
DIMM SPD fatal error. Probable Cause: Detection of SPD error type - various types
Recommended Action: Reseat or replace the DIMM. If problem persists, contact HP
Support personnel to troubleshoot the problem WBEM EventID: 302. WBEM
ProviderName: FPL_IndicationProvider
Warning
5173
Unsupported memory DIMM type. Probable Cause: A DIMM with an invalid DIMM
type was found Recommended Action: Contact HP Support personnel to troubleshoot
the problem WBEM EventID: 303. WBEM ProviderName: FPL_IndicationProvider
Warning
5174
The DIMM type of this DIMM doesn't match with others in the DIMM group. Probable
Cause: The DIMMs in the rank do not have the same DIMM type Recommended
Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID:
304. WBEM ProviderName: FPL_IndicationProvider
Warning
5175
The DIMM type table is full. New DIMM type cannot be added. Probable Cause: Too
many different types of DIMMs in system Recommended Action: Reduce the number
of different types of DIMMs in the system. WBEM EventID: 305. WBEM
ProviderName: FPL_IndicationProvider
Warning
5176
DIMM number not found in DMT Table. Probable Cause:. Probable internal FW error
Recommended Action: Reload System Firmware Recommended Action: Contact HP
Support personnel to troubleshoot the problem WBEM EventID: 306. WBEM
ProviderName: FPL_IndicationProvider
Warning
5179
Platform Events
19