HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 19
DIMM number not found in DMT Table. Probable Cause:. Probable internal FW error - user manual
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Event ID Event Severity Event Description 5155 Error Error in temporary mdt area. Probable Cause: The memory area where the MDT is supposed to be built has an error in it, so the MDT cannot be built there. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProvider 5156 Error Failed to find lmmio entry in mdt. Probable Cause: The MDT table is bad because it did not have an LMMIO entry in it. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 294. WBEM ProviderName: FPL_IndicationProvider 5157 Error Memory page zero bad. Probable Cause: Memory page 0 was slated for deallocation in the PDT. Recommended Action: FW is written such that this event should never be generated. If the user sees this event, please contact HP support. WBEM EventID: 295. WBEM ProviderName: FPL_IndicationProvider 5158 Error Failed to find space in mdt. Probable Cause: FW requested an entry in the MDT, and there wasn't a large enough chunk of contiguous memory for the requested size. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 296. WBEM ProviderName: FPL_IndicationProvider 5159 Warning Media failure: info was not retrieved/logged. Probable Cause: The Error handler has failed to retrieve or log data due to a media failure. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 297. WBEM ProviderName: FPL_IndicationProvider 5160 Warning Bus interface register test failed. Probable Cause: The CEC failed the register test. Recommended Action: Contact HP support to troubleshoot the problem. WBEM EventID: 298. WBEM ProviderName: FPL_IndicationProvider 5161 Warning Memory ECC normal write/read test failed. Probable Cause: The DIMM that maps to cache line 0 is in a chipspare condition Recommended Action: Contact HP support WBEM EventID: 299. WBEM ProviderName: FPL_IndicationProvider 5171 Warning DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM is not loaded in order to allow for proper operation of the DIMM specified in the physical location. Recommended Action: Refer to the user's manual for Memory loading instructions. WBEM EventID: 300. WBEM ProviderName: FPL_IndicationProvider 5172 Warning DIMM SPD checksum failed. Probable Cause: The DIMMs SPD EEPROM got corrupted. Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 301. WBEM ProviderName: FPL_IndicationProvider 5173 Warning DIMM SPD fatal error. Probable Cause: Detection of SPD error type - various types Recommended Action: Reseat or replace the DIMM. If problem persists, contact HP Support personnel to troubleshoot the problem WBEM EventID: 302. WBEM ProviderName: FPL_IndicationProvider 5174 Warning Unsupported memory DIMM type. Probable Cause: A DIMM with an invalid DIMM type was found Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 303. WBEM ProviderName: FPL_IndicationProvider 5175 Warning The DIMM type of this DIMM doesn't match with others in the DIMM group. Probable Cause: The DIMMs in the rank do not have the same DIMM type Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 304. WBEM ProviderName: FPL_IndicationProvider 5176 Warning The DIMM type table is full. New DIMM type cannot be added. Probable Cause: Too many different types of DIMMs in system Recommended Action: Reduce the number of different types of DIMMs in the system. WBEM EventID: 305. WBEM ProviderName: FPL_IndicationProvider 5179 Warning DIMM number not found in DMT Table. Probable Cause:. Probable internal FW error Recommended Action: Reload System Firmware Recommended Action: Contact HP Support personnel to troubleshoot the problem WBEM EventID: 306. WBEM ProviderName: FPL_IndicationProvider Platform Events 19