HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 75
Error reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: xbcNum 32
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Event ID Event Severity Event Description 10389 Warning Error reading Skyline ALREC_ALB_ID CSR. Data field: (Skyline port) | (Cell number 56). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2931. WBEM ProviderName: FPL_IndicationProvider 10390 Warning A circular route was found while testing XBC CSR traffic traversability. Data field: (target XBC 32) | (cellNum 56). Probable Cause: Internal firmware error, fabric was routed incorrectly. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2932. WBEM ProviderName: FPL_IndicationProvider 10391 Warning Error reading ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2933. WBEM ProviderName: FPL_IndicationProvider 10392 Warning An XBC-XBC port had an invalid chip type connection. Data field: (expected chip type) | (actual chip type 32). Probable Cause: System firmware found a discrepancy in the system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2934. WBEM ProviderName: FPL_IndicationProvider 10393 Warning ArfIsXbcRouteTraversable was called on a back-to-back system which is an improper use of the function. Data field: unused. Probable Cause: Internal firmware error. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2935. WBEM ProviderName: FPL_IndicationProvider 10394 Warning In ArfIsXbcRouteTraversable, an XBC-XBC link was found to have fatal errors. Data field: (xbcNum 32) | (portNum 48). Probable Cause: A previously healthy link was found to have fatal errors. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2936. WBEM ProviderName: FPL_IndicationProvider 10395 Warning Unable to read the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2937. WBEM ProviderName: FPL_IndicationProvider 10396 Warning Error reading an XBC ROUTE_TABLE CSR. Data field: route index | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2938. WBEM ProviderName: FPL_IndicationProvider 10397 Warning Error reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2939. WBEM ProviderName: FPL_IndicationProvider 10398 Warning An XBC port was found with an unexpected neighbor chip. Data field: expected chip type | (actual chip type 32). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2940. WBEM ProviderName: FPL_IndicationProvider 10401 Warning A cell/port pair was not found in the expected graph data. Data field: (cellNum 32) | CC portNum. Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2942. WBEM ProviderName: FPL_IndicationProvider Platform Events 75