HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 70

Failed to read the XBC CSR High Severity Error Log State. Probable Cause: Fabric

Page 70 highlights

Event ID Event Severity Event Description 9781 Warning Failed to copy the XBC CSR Error Symbol01 Block. Probable Cause: Fabric Access Failure; Possibly an invalid destination address. Check hardware, Contact HP Support WBEM EventID: 1833. WBEM ProviderName: FPL_IndicationProvider 9782 Warning Failed to copy the XBC CSR Error Symbol23 Block. Probable Cause: Fabric Access Failure; Possibly an invalid destination address. Check hardware, Contact HP Support WBEM EventID: 1834. WBEM ProviderName: FPL_IndicationProvider 9783 Warning Failed to reset the XBC Low Severity Error Log State. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1835. WBEM ProviderName: FPL_IndicationProvider 9784 Warning Failed to clear the XBC Low Severity Log Symbol 01. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Backplane WBEM EventID: 1836. WBEM ProviderName: FPL_IndicationProvider 9785 Warning Could not determine if there is a new XBC CSR Low Severity error. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1837. WBEM ProviderName: FPL_IndicationProvider 9786 Warning Failed to read the XBC CSR Low Severity Error Log State. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1838. WBEM ProviderName: FPL_IndicationProvider 9787 Warning Failed to reset the XBC Low Severity Error Log State. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1839. WBEM ProviderName: FPL_IndicationProvider 9788 Warning Could not determine if there is a new XBC CSR High Severity error. Probable Cause: Check XBC, Flex Cables, Backplane Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1840. WBEM ProviderName: FPL_IndicationProvider 9789 Warning Failed to read the XBC CSR High Severity Error Log State. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1841. WBEM ProviderName: FPL_IndicationProvider 9801 Error An error occurred while enabling hashing in the platform cache. Probable Cause: An error return status. This could happen if the tree was corrupted or there was an error verifying the hashing setting. Recommended Action: reset the partition WBEM EventID: 1842. WBEM ProviderName: FPL_IndicationProvider 9827 Warning The XBC CSR is not a valid CSR address. Probable Cause: Invalid CSR address, possible firmware defect. Recommended Action: Capture complete live logs and contact HP Support representative. WBEM EventID: 1843. WBEM ProviderName: FPL_IndicationProvider 9832 Error It indicates loss of cell connectivity in the partition. Probable Cause: It will lead to cells performing RESET_FOR_RECONFIG after getting the error logs. WBEM EventID: 2448. WBEM ProviderName: FPL_IndicationProvider 9849 Error Error building cell-level FW device tree. Probable Cause: Data field displays the status of creating the cell level device tree for use by firmware. See previous errors already reported. WBEM EventID: 2450. WBEM ProviderName: FPL_IndicationProvider 9867 Warning CPU deconfigured during FSB interface initialization. Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. WBEM EventID: 1845. WBEM ProviderName: FPL_IndicationProvider 70 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Failed to copy the XBC CSR Error Symbol01 Block. Probable Cause: Fabric Access
Failure; Possibly an invalid destination address. Check hardware, Contact HP Support
WBEM EventID: 1833. WBEM ProviderName: FPL_IndicationProvider
Warning
9781
Failed to copy the XBC CSR Error Symbol23 Block. Probable Cause: Fabric Access
Failure; Possibly an invalid destination address. Check hardware, Contact HP Support
WBEM EventID: 1834. WBEM ProviderName: FPL_IndicationProvider
Warning
9782
Failed to reset the XBC Low Severity Error Log State. Probable Cause: Fabric Access
Failure. Recommended Action: Contact HP Support personnel to check the XBC,
Flex Cables, Backplane WBEM EventID: 1835. WBEM ProviderName:
FPL_IndicationProvider
Warning
9783
Failed to clear the XBC Low Severity Log Symbol 01. Probable Cause: Fabric Access
Failure. Recommended Action: Contact HP Support personnel to check the XBC,
Backplane WBEM EventID: 1836. WBEM ProviderName: FPL_IndicationProvider
Warning
9784
Could not determine if there is a new XBC CSR Low Severity error. Probable Cause:
Fabric Access Failure. Recommended Action: Contact HP Support personnel to check
the XBC, Flex Cables, Backplane WBEM EventID: 1837. WBEM ProviderName:
FPL_IndicationProvider
Warning
9785
Failed to read the XBC CSR Low Severity Error Log State. Probable Cause: Fabric
Access Failure. Recommended Action: Contact HP Support personnel to check the
XBC, Flex Cables, Backplane WBEM EventID: 1838. WBEM ProviderName:
FPL_IndicationProvider
Warning
9786
Failed to reset the XBC Low Severity Error Log State. Probable Cause: Fabric Access
Failure. Recommended Action: Contact HP Support personnel to check the XBC,
Flex Cables, Backplane WBEM EventID: 1839. WBEM ProviderName:
FPL_IndicationProvider
Warning
9787
Could not determine if there is a new XBC CSR High Severity error. Probable Cause:
Check XBC, Flex Cables, Backplane Recommended Action: Contact HP Support
personnel to check the XBC, Flex Cables, Backplane WBEM EventID: 1840. WBEM
ProviderName: FPL_IndicationProvider
Warning
9788
Failed to read the XBC CSR High Severity Error Log State. Probable Cause: Fabric
Access Failure. Recommended Action: Contact HP Support personnel to check the
XBC, Flex Cables, Backplane WBEM EventID: 1841. WBEM ProviderName:
FPL_IndicationProvider
Warning
9789
An error occurred while enabling hashing in the platform cache. Probable Cause: An
error return status. This could happen if the tree was corrupted or there was an error
verifying the hashing setting. Recommended Action: reset the partition WBEM
EventID: 1842. WBEM ProviderName: FPL_IndicationProvider
Error
9801
The XBC CSR is not a valid CSR address. Probable Cause: Invalid CSR address,
possible firmware defect. Recommended Action: Capture complete live logs and
contact HP Support representative. WBEM EventID: 1843. WBEM ProviderName:
FPL_IndicationProvider
Warning
9827
It indicates loss of cell connectivity in the partition. Probable Cause: It will lead to
cells performing RESET_FOR_RECONFIG after getting the error logs. WBEM EventID:
2448. WBEM ProviderName: FPL_IndicationProvider
Error
9832
Error building cell-level FW device tree. Probable Cause: Data field displays the
status of creating the cell level device tree for use by firmware. See previous errors
already reported. WBEM EventID: 2450. WBEM ProviderName:
FPL_IndicationProvider
Error
9849
CPU deconfigured during FSB interface initialization. Probable Cause: internal error.
Recommended Action: the CPU will be deconfigured. If the error persists after a
powercycle, contact HP Support. WBEM EventID: 1845. WBEM ProviderName:
FPL_IndicationProvider
Warning
9867
70
WBEM Provider Event Tables