HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 24
Parity error in Reg FIFO Internal parity error. Probable Cause: Parity error in Reg
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Event ID Event Severity Event Description 5411 Error A CPU has taken over for the monarch CPU. Probable Cause: The previous monarch may be suspect. WBEM EventID: 365. WBEM ProviderName: FPL_IndicationProvider 5416 Error Sram cannot be used on the cell. Probable Cause: SRAM cannot be located or used on the cell board. Replace the cell board. WBEM EventID: 366. WBEM ProviderName: FPL_IndicationProvider 5417 Error The dillon hardware cannot be located. Probable Cause: ROM is corrupt. Replace the rom or reprogram flash. WBEM EventID: 367. WBEM ProviderName: FPL_IndicationProvider 5418 Error A required piece of PDH bus hardware cannot be contacted. Probable Cause: Verify all connections of PDH bus components or replace the cell board. WBEM EventID: 368. WBEM ProviderName: FPL_IndicationProvider 5419 Warning Error: PCI Buses are configured for multiple speeds. Probable Cause: A PCI card is configured with mixed speeds. Recommended Action: Correct the configuration problem. WBEM EventID: 2420. WBEM ProviderName: FPL_IndicationProvider 5420 Error The bus depth was exceeded during IO probing. Probable Cause: Too many PCI bridge cards are configured in single PCI segment mode. Recommended Action: Reconfigure PCI cards and remove some of the bridge devices. WBEM EventID: 2421. WBEM ProviderName: FPL_IndicationProvider 5432 Error A Timeout occurred during RI initialization. The CSR is in the data field. The alert level will vary. Probable Cause: Hardware problem such as cable connect error or bad cables. Recommended Action: Correct the hardware problem and re-boot. WBEM EventID: 2422. WBEM ProviderName: FPL_IndicationProvider 5438 Warning SuperIO has been detected in slot. Probable Cause: SuperIO has been detected in the PCI slot. Recommended Action: No action required, information only. WBEM EventID: 2423. WBEM ProviderName: FPL_IndicationProvider 5440 Warning IO Link software error was corrected. Probable Cause: IO link error was detected and corrected. Recommended Action: No action required, information only. WBEM EventID: 372. WBEM ProviderName: FPL_IndicationProvider 5442 Error Parity error in Reg FIFO Internal parity error. Probable Cause: Parity error in Reg FIFO. Recommended Action: Replace bad hardware. WBEM EventID: 374. WBEM ProviderName: FPL_IndicationProvider 5443 Error TLB Fetch timeout. Probable Cause: SBA TLB fetch timeout error. Recommended Action: Replace faulty hardware. WBEM EventID: 375. WBEM ProviderName: FPL_IndicationProvider 5444 Error Link presence goes away, FE. Probable Cause: Link presence lost on SBA interface. Recommended Action: Replace faulty hardware. WBEM EventID: 376. WBEM ProviderName: FPL_IndicationProvider 5445 Error Elroy to REO parity error on command, rope will go fatal. Probable Cause: Bad hardware. Recommended Action: Replace I/O chassis. WBEM EventID: 377. WBEM ProviderName: FPL_IndicationProvider 5446 Error Access to invalid TLB entry Requesting rope fatal. Probable Cause: An IO device is requesting access to an invalid TLB entry. Recommended Action: Driver problem debug driver. WBEM EventID: 378. WBEM ProviderName: FPL_IndicationProvider 5447 Error Memory fetch timeout. Probable Cause: SBA memory fetch timeout error Recommended Action: repair faulty hardware WBEM EventID: 379. WBEM ProviderName: FPL_IndicationProvider 5448 Error Error was encountered when Initializing the LBA. Probable Cause: LBA firmware initialization failed Recommended Action: Review additional error logs to determine exact cause of failure. WBEM EventID: 380. WBEM ProviderName: FPL_IndicationProvider 24 WBEM Provider Event Tables