HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 77
Error writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: route set, In SetupNCTable
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
Event ID Event Severity Event Description 10414 Warning In SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data field: (data written to CSR) | (actual CSR data read 32). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2952. WBEM ProviderName: FPL_IndicationProvider 10415 Warning SetupNCTable failed in ArfPhase3. Data field: cell set passed in to SetupNCTable. Probable Cause: System firmware was unable to write some fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2953. WBEM ProviderName: FPL_IndicationProvider 10427 Warning A failure occurred while prepping a back-to-back system for post-rendezvous Arches Fabric setup. Data field: return value from Phase4BackToBackPrep. Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2954. WBEM ProviderName: FPL_IndicationProvider 10429 Warning ArfPhase4 was unable to set up the Non-Coherent link select to at least one cell in its alive/gsm sharing set. Data field: bitmap of unreachable cells. Probable Cause: System firmware was unable to find valid routes to each cell in a previously good partition. Possible cable/connection problems. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2955. WBEM ProviderName: FPL_IndicationProvider 10431 Warning Unable to set the Non-Coherent route. Data field: (sourceCell 32) | (cell set passed in to SetupNCTable). Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2956. WBEM ProviderName: FPL_IndicationProvider 10432 Warning Unable to setup the Coherent route table for a cell in our partition. Data field: (sourceCell 32) | (cell set passed in to SetupCohTable). Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2957. WBEM ProviderName: FPL_IndicationProvider 10435 Warning Error writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (route set to disable) | (xbcNum 32) | (xbc port 48). Probable Cause: System firmware was unable to write various fabric hardware registers. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2958. WBEM ProviderName: FPL_IndicationProvider 10436 Warning The Arches Fabric vertex module returned an unexpected error during Non-Coherent table setup. Data field: (return value) | (sourceCell 32) | (dest cell 48). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2959. WBEM ProviderName: FPL_IndicationProvider 10439 Warning A write to a Skyline Global LINK_SEL_COHx CSR failed. Data field: cell number of the Skyline that failed. Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2960. WBEM ProviderName: FPL_IndicationProvider 10475 Warning Unable to write the XBC port scratch CSR with the routing state. Data field: (routing state) | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to write a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric WBEM EventID: 2962. WBEM ProviderName: FPL_IndicationProvider Platform Events 77