HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 60

New for MtWhatever: BOOT_BAD_CPU_ORDER. Probable Cause: Check CPU load

Page 60 highlights

Event ID Event Severity Event Description 9040 Warning Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction between any of these cell components. Recommended Action: Troubleshoot the cell and either fix it or replace it. WBEM EventID: 897. WBEM ProviderName: FPL_IndicationProvider 9041 Warning Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really could have. Recommended Action: Upgrade PDC if this is found to be the problem and a new PDC image is available. WBEM EventID: 898. WBEM ProviderName: FPL_IndicationProvider 9042 Warning Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: PDC bug in which PDC thinks it was unable to safely access PDH memory when maybe it really could have. Recommended Action: Upgrade PDC if this is found to be the problem and a new PDC image is available. WBEM EventID: 899. WBEM ProviderName: FPL_IndicationProvider 9043 Warning A reset for reconfiguration will be performed soon on the cell. Probable Cause: An error during cell initialization occurred and the cell will not be able to join the partition. Look for other errors in the event log that articulate the exact problem. WBEM EventID: 900. WBEM ProviderName: FPL_IndicationProvider 9045 Warning The Partition Profile specifies the wrong architecture type. Probable Cause: This is caused by the wrong type of complex profile being loaded. System firmware will default a new partition profile and continue on. WBEM EventID: 901. WBEM ProviderName: FPL_IndicationProvider 9046 Warning Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable Cause: Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the concorde or CPU chips. Recommended Action: Troubleshoot the cell and either fix cell or replace the cell board. WBEM EventID: 902. WBEM ProviderName: FPL_IndicationProvider 9047 Warning Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable Cause: PDC problem such that PDC is passing bad data from one function to another. Recommended Action: Upgrade PDC. WBEM EventID: 903. WBEM ProviderName: FPL_IndicationProvider 9049 Warning Cell/Partition about to be reset because PDC is unable to access CPU data. Probable Cause: Cell hardware problem, like a problem with PDH registers or PDH memory, or a problem with the concorde or CPU chips. Recommended Action: Troubleshoot the cell and either fix cell or replace the cell board. WBEM EventID: 904. WBEM ProviderName: FPL_IndicationProvider 9051 Warning Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable Cause: PDC problem such that PDC is passing bad data from one function to another. Recommended Action: Upgrade PDC. WBEM EventID: 905. WBEM ProviderName: FPL_IndicationProvider 9052 Warning PDC is unable to branch to other software via the Page Zero location. Probable Cause: The MEM_RENDEZ fields of Page Zero were programmed incorrectly. Recommended Action: Upgrade or patch the OS. WBEM EventID: 906. WBEM ProviderName: FPL_IndicationProvider 9084 Error New for MtWhatever: BOOT_BAD_CPU_ORDER. Probable Cause: Check CPU load ordering WBEM EventID: 2686. WBEM ProviderName: FPL_IndicationProvider 9364 Warning PDC couldn't access a data structure in PDH memory. Probable Cause: PDC bug in which PDC is trying to access PDH memory of a cell not in its partition. Recommended Action: Upgrade PDC if there is a version of PDC that fixes such a problem. WBEM EventID: 908. WBEM ProviderName: FPL_IndicationProvider 9365 Warning PDC couldn't access a data structure in PDH memory. Probable Cause: Hardware problem with the CPU or cell board. Recommended Action: Contact HP Support to confirm the CPUs and cell board are functioning properly. WBEM EventID: 909. WBEM ProviderName: FPL_IndicationProvider 60 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or
interaction between any of these cell components. Recommended Action: Troubleshoot
the cell and either fix it or replace it. WBEM EventID: 897. WBEM ProviderName:
FPL_IndicationProvider
Warning
9040
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
PDC bug in which PDC thinks it was unable to safely access PDH memory when
maybe it really could have. Recommended Action: Upgrade PDC if this is found to
be the problem and a new PDC image is available. WBEM EventID: 898. WBEM
ProviderName: FPL_IndicationProvider
Warning
9041
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
PDC bug in which PDC thinks it was unable to safely access PDH memory when
maybe it really could have. Recommended Action: Upgrade PDC if this is found to
be the problem and a new PDC image is available. WBEM EventID: 899. WBEM
ProviderName: FPL_IndicationProvider
Warning
9042
A reset for reconfiguration will be performed soon on the cell. Probable Cause: An
error during cell initialization occurred and the cell will not be able to join the
partition. Look for other errors in the event log that articulate the exact problem.
WBEM EventID: 900. WBEM ProviderName: FPL_IndicationProvider
Warning
9043
The Partition Profile specifies the wrong architecture type. Probable Cause: This is
caused by the wrong type of complex profile being loaded. System firmware will
default a new partition profile and continue on. WBEM EventID: 901. WBEM
ProviderName: FPL_IndicationProvider
Warning
9045
Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable
Cause: Cell hardware problem, like a problem with PDH registers or PDH memory,
or a problem with the concorde or CPU chips. Recommended Action: Troubleshoot
the cell and either fix cell or replace the cell board. WBEM EventID: 902. WBEM
ProviderName: FPL_IndicationProvider
Warning
9046
Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable
Cause: PDC problem such that PDC is passing bad data from one function to another.
Recommended Action: Upgrade PDC. WBEM EventID: 903. WBEM ProviderName:
FPL_IndicationProvider
Warning
9047
Cell/Partition about to be reset because PDC is unable to access CPU data. Probable
Cause: Cell hardware problem, like a problem with PDH registers or PDH memory,
or a problem with the concorde or CPU chips. Recommended Action: Troubleshoot
the cell and either fix cell or replace the cell board. WBEM EventID: 904. WBEM
ProviderName: FPL_IndicationProvider
Warning
9049
Cell/Partition is about to be reset because PDC is unable to access CPU data. Probable
Cause: PDC problem such that PDC is passing bad data from one function to another.
Recommended Action: Upgrade PDC. WBEM EventID: 905. WBEM ProviderName:
FPL_IndicationProvider
Warning
9051
PDC is unable to branch to other software via the Page Zero location. Probable Cause:
The MEM_RENDEZ fields of Page Zero were programmed incorrectly. Recommended
Action: Upgrade or patch the OS. WBEM EventID: 906. WBEM ProviderName:
FPL_IndicationProvider
Warning
9052
New for MtWhatever: BOOT_BAD_CPU_ORDER. Probable Cause: Check CPU load
ordering WBEM EventID: 2686. WBEM ProviderName: FPL_IndicationProvider
Error
9084
PDC couldn't access a data structure in PDH memory. Probable Cause: PDC bug in
which PDC is trying to access PDH memory of a cell not in its partition. Recommended
Action: Upgrade PDC if there is a version of PDC that fixes such a problem. WBEM
EventID: 908. WBEM ProviderName: FPL_IndicationProvider
Warning
9364
PDC couldn't access a data structure in PDH memory. Probable Cause: Hardware
problem with the CPU or cell board. Recommended Action: Contact HP Support to
confirm the CPUs and cell board are functioning properly. WBEM EventID: 909.
WBEM ProviderName: FPL_IndicationProvider
Warning
9365
60
WBEM Provider Event Tables