HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 55

Recommended Action: Reseat Card. Replace Card. If error persists, contact HP

Page 55 highlights

Event ID Event Severity Event Description 8798 Warning Firmware could not set Pal Proc features. Probable Cause: FW MCA code uses this PAL_SET_PROC_FEATURES to escalate future MCA to BINIT. This event id when emitted during an MCA processing means that any subsequent global MCA would not cause all the processors in the PD to MCA again. WBEM EventID: 2443. WBEM ProviderName: FPL_IndicationProvider 8806 Warning Means that the error log space in the Nvram has not been allocated. Probable Cause: This happens because of the NVRAM is full with unconsumed error logs. Clear the error logs. WBEM EventID: 824. WBEM ProviderName: FPL_IndicationProvider 8807 Warning This indicates the maximum number of logs for the event. Probable Cause: This shouldn't be occur. But in case it does than clear the error logs of this event type from the nvram. WBEM EventID: 825. WBEM ProviderName: FPL_IndicationProvider 8814 Warning On Line Delete operation was begun but firmware couldn't find a deleteable cell. Probable Cause: This can occur if the OS has not returned all the CPUs to firmware or if a cell is not marked correctly in the complex profile to allow its deletion. WBEM EventID: 826. WBEM ProviderName: FPL_IndicationProvider 8817 Error The bulk power system is above its current capacity. Probable Cause: N/A WBEM EventID: 827. WBEM ProviderName: FPL_IndicationProvider 8818 Warning The bulk specified is warning of a potential thermal problem. Probable Cause: The bulk power supply is warning of an over temperature condition WBEM EventID: 828. WBEM ProviderName: FPL_IndicationProvider 8819 Error Malloc failed while trying to process and ERM. Probable Cause: Heap space is completely used or corrupt. Contact Product Engineering. WBEM EventID: 829. WBEM ProviderName: FPL_IndicationProvider 8821 Warning Dimm at physical location in data field is not supported on this platform. Probable Cause: Unsupported dimm in specified slot Recommended Action: Replace dimm with supported dimm. WBEM EventID: 830. WBEM ProviderName: FPL_IndicationProvider 8828 Error The OPTIONS component received a memory allocation error. Probable Cause: Invalidate NVRAM and reset. WBEM EventID: 831. WBEM ProviderName: FPL_IndicationProvider 8837 Warning A dimm or CPU has been deconfigured or failed testing. Probable Cause: A deconfigured dimm or cpu has been detected. Examine earlier events to isolate the problem. WBEM EventID: 832. WBEM ProviderName: FPL_IndicationProvider 8839 Error The cell will not join the PD. Probable Cause: Broken hardware was detected and the cell integration policy combined to cause the cell to not join the PD. Recommended Action: Fix the broken hardware or change the policy using parmgr. If assistance is required, contact the HP Support Center. WBEM EventID: 833. WBEM ProviderName: FPL_IndicationProvider 8842 Warning The error context in NVM was corrupt. Probable Cause: NVM is corrupted. Recommended Action: Check for other errors in the system first. Invalidate NVM and retry boot. Get the latest firmware release. WBEM EventID: 834. WBEM ProviderName: FPL_IndicationProvider 8843 Warning A rope went fatal from the SBA. Probable Cause: Mainly a hardware problem causes this problem. Recommended Action: Replace I/O chassis. WBEM EventID: 835. WBEM ProviderName: FPL_IndicationProvider 8844 Warning A PCI bus on the system went fatal. Probable Cause: A bad card, a bad device, or a system hardware problem can cause this to occur. Card will be powered off (if possible) and the attention light on the slot will be lit indicating an error. Recommended Action: Reseat Card. Replace Card. If error persists, contact HP support. WBEM EventID: 1763. WBEM ProviderName: FPL_IndicationProvider 8845 Warning One of the rope units in the SBA is dead. Probable Cause: Usually hardware. WBEM EventID: 836. WBEM ProviderName: FPL_IndicationProvider Platform Events 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Firmware could not set Pal Proc features. Probable Cause: FW MCA code uses this
PAL_SET_PROC_FEATURES to escalate future MCA to BINIT. This event id when
emitted during an MCA processing means that any subsequent global MCA would
not cause all the processors in the PD to MCA again. WBEM EventID: 2443. WBEM
ProviderName: FPL_IndicationProvider
Warning
8798
Means that the error log space in the Nvram has not been allocated. Probable Cause:
This happens because of the NVRAM is full with unconsumed error logs. Clear the
error logs. WBEM EventID: 824. WBEM ProviderName: FPL_IndicationProvider
Warning
8806
This indicates the maximum number of logs for the event. Probable Cause: This
shouldn't be occur. But in case it does than clear the error logs of this event type from
the nvram. WBEM EventID: 825. WBEM ProviderName: FPL_IndicationProvider
Warning
8807
On Line Delete operation was begun but firmware couldn't find a deleteable cell.
Probable Cause: This can occur if the OS has not returned all the CPUs to firmware
or if a cell is not marked correctly in the complex profile to allow its deletion. WBEM
EventID: 826. WBEM ProviderName: FPL_IndicationProvider
Warning
8814
The bulk power system is above its current capacity. Probable Cause: N/A WBEM
EventID: 827. WBEM ProviderName: FPL_IndicationProvider
Error
8817
The bulk specified is warning of a potential thermal problem. Probable Cause: The
bulk power supply is warning of an over temperature condition WBEM EventID:
828. WBEM ProviderName: FPL_IndicationProvider
Warning
8818
Malloc failed while trying to process and ERM. Probable Cause: Heap space is
completely used or corrupt. Contact Product Engineering. WBEM EventID: 829.
WBEM ProviderName: FPL_IndicationProvider
Error
8819
Dimm at physical location in data field is not supported on this platform. Probable
Cause: Unsupported dimm in specified slot Recommended Action: Replace dimm
with supported dimm. WBEM EventID: 830. WBEM ProviderName:
FPL_IndicationProvider
Warning
8821
The OPTIONS component received a memory allocation error. Probable Cause:
Invalidate NVRAM and reset. WBEM EventID: 831. WBEM ProviderName:
FPL_IndicationProvider
Error
8828
A dimm or CPU has been deconfigured or failed testing. Probable Cause: A
deconfigured dimm or cpu has been detected. Examine earlier events to isolate the
problem. WBEM EventID: 832. WBEM ProviderName: FPL_IndicationProvider
Warning
8837
The cell will not join the PD. Probable Cause: Broken hardware was detected and
the cell integration policy combined to cause the cell to not join the PD. Recommended
Action: Fix the broken hardware or change the policy using parmgr. If assistance is
required, contact the HP Support Center. WBEM EventID: 833. WBEM ProviderName:
FPL_IndicationProvider
Error
8839
The error context in NVM was corrupt. Probable Cause: NVM is corrupted.
Recommended Action: Check for other errors in the system first. Invalidate NVM
and retry boot. Get the latest firmware release. WBEM EventID: 834. WBEM
ProviderName: FPL_IndicationProvider
Warning
8842
A rope went fatal from the SBA. Probable Cause: Mainly a hardware problem causes
this problem. Recommended Action: Replace I/O chassis. WBEM EventID: 835. WBEM
ProviderName: FPL_IndicationProvider
Warning
8843
A PCI bus on the system went fatal. Probable Cause: A bad card, a bad device, or a
system hardware problem can cause this to occur. Card will be powered off (if
possible) and the attention light on the slot will be lit indicating an error.
Recommended Action: Reseat Card. Replace Card. If error persists, contact HP
support. WBEM EventID: 1763. WBEM ProviderName: FPL_IndicationProvider
Warning
8844
One of the rope units in the SBA is dead. Probable Cause: Usually hardware. WBEM
EventID: 836. WBEM ProviderName: FPL_IndicationProvider
Warning
8845
Platform Events
55