HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 59
Table #2, Event ID numbers 9, 000 through 12
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Event ID Event Severity Event Description 8976 Warning Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 884. WBEM ProviderName: FPL_IndicationProvider 8979 Warning The CPU is performance or functionally restricted. Probable Cause: A CPU is broken. Replace it. WBEM EventID: 885. WBEM ProviderName: FPL_IndicationProvider 8981 Warning The RTC was found to be invalid and has been cleared. Probable Cause: The RTC was invalid Recommended Action: No action is required. The problem has been corrected by SFW. WBEM EventID: 886. WBEM ProviderName: FPL_IndicationProvider 8982 Warning Status indicates that the Late Self Tests did not actually run. Probable Cause: This could be caused by an incompatibity problem between PAL and the CPUs. Check that PAL supports all the CPUs installed on the system. WBEM EventID: 887. WBEM ProviderName: FPL_IndicationProvider 8983 Error A fabric walk failed while updating the cell state. Probable Cause: Look for adjacent chassis codes to determine the cause of FabricWalk failure. Check the backplane and fabric connectivity. Contact the HP Support Personnel for further troubleshooting. WBEM EventID: 888. WBEM ProviderName: FPL_IndicationProvider 8984 Error Could not reset the cell due to failure updating cell state. Probable Cause: Most likely a failure on the fabric or on the CC. Fabric failures should produce additional chassis codes. If no additional chassis codes indicate the cause of the failure, then contact the HP Support Personnel for further troubleshooting. WBEM EventID: 889. WBEM ProviderName: FPL_IndicationProvider Table #2 - Event ID numbers 9,000 through 12,627 Event ID Event Severity Event Description 9000 Warning DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing DIMM Recommended Action: Replace the DIMM flagged by SFW WBEM EventID: 890. WBEM ProviderName: FPL_IndicationProvider 9019 Error System Clocks are not valid. Probable Cause: The Cell board has a problem. Either the Real Time Clock is not working properly or the system is not being clocked at the value it thinks it is. WBEM EventID: 891. WBEM ProviderName: FPL_IndicationProvider 9020 Error Cell Online Addition failed due to fabric access error. Probable Cause: Fabric Access Failure, Recommended Action: Check CC to CC link. Look for additional failure chassis codes to provide more detail. WBEM EventID: 892. WBEM ProviderName: FPL_IndicationProvider 9021 Error Fabric found a bad XBC port on a reboot. Attempting to route around it. Probable Cause: link errors. Recommended Action: Run DC Connectivity test. Check flex cables, XBCs, and CCs. WBEM EventID: 893. WBEM ProviderName: FPL_IndicationProvider 9022 Warning Could not access an internal firmware table while rerouting XBC port. Probable Cause: Firmware Error. Recommended Action: Capture chassis codes and contact HP Support. WBEM EventID: 894. WBEM ProviderName: FPL_IndicationProvider 9038 Warning Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: Cell hardware problem like PDH memory itself, the coherency controller, the executing CPU or interaction between any of these cell components. Recommended Action: Contact HP Support to troubleshoot the cell and either fix it or replace it. WBEM EventID: 895. WBEM ProviderName: FPL_IndicationProvider 9039 Warning Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause: Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or interaction between any of these cell components. Recommended Action: Troubleshoot the cell and either fix it or replace it. WBEM EventID: 896. WBEM ProviderName: FPL_IndicationProvider Platform Events 59