HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 79
Failed to write the XBC Global Semaphore. Probable Cause: write to XBC failed
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Event ID Event Severity Event Description 10523 Warning Failure to get the XBC Global Semaphore address. Probable Cause: Failed to get a fabric address Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4852. WBEM ProviderName: FPL_IndicationProvider 10524 Warning Failed to write the XBC Global Semaphore. Probable Cause: write to XBC failed Recommended Action: Contact HP Support personnel to check the XBC WBEM EventID: 4853. WBEM ProviderName: FPL_IndicationProvider 10528 Warning Failed to read the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. WBEM EventID: 4854. WBEM ProviderName: FPL_IndicationProvider 10529 Warning Failed to get the address of the XBC Global Semaphore. Probable Cause: Failed to get a fabric address Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4855. WBEM ProviderName: FPL_IndicationProvider 10530 Warning Failed to write the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. WBEM EventID: 4856. WBEM ProviderName: FPL_IndicationProvider 10532 Warning Failed to release the XBC Global Semaphore. Probable Cause: System Firmware was unable to release a XBC semaphore Recommended Action: Collect IPMI Event Logs. Contact HP Support Representative to investigate the fabric. WBEM EventID: 4857. WBEM ProviderName: FPL_IndicationProvider 10534 Warning Fabric phases have been executed in an invalid order. Probable Cause: System firmware failed a validation check on its routing progress Recommended Action: Collect all IPMI event logs, preferably live logs. Contact you HP Support Representative WBEM EventID: 4858. WBEM ProviderName: FPL_IndicationProvider 10535 Warning Fabric phases have been executed in an invalid order. Data field indicates the expected phase. Probable Cause: System firmware failed a validation check on its routing progress Recommended Action: Collect all IPMI event logs, preferably live logs. Contact you HP Support Representative WBEM EventID: 4859. WBEM ProviderName: FPL_IndicationProvider 10558 Warning Failed to get an address when opening XBC to XBC links. Probable Cause: Failed to get a fabric address Recommended Action: Look for additional IPMI event logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4885. WBEM ProviderName: FPL_IndicationProvider 10559 Warning Failed to open a fabric link. Probable Cause: System Firmware was unable to open the crossbar link Recommended Action: Collect IPMI Event Logs. Contact your HP Support Representative to analyze the fabric. WBEM EventID: 4895. WBEM ProviderName: FPL_IndicationProvider 10560 Warning Error when writing the XBC return route. Probable Cause: write to XBC failed Recommended Action: Contact HP Support personnel to check the XBC WBEM EventID: 4897. WBEM ProviderName: FPL_IndicationProvider 10561 Warning Error enabling the XBC return route. Probable Cause: write to XBC failed Recommended Action: Contact HP Support personnel to check the XBC WBEM EventID: 4896. WBEM ProviderName: FPL_IndicationProvider 10564 Warning Failed to disperse the routes across links. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. WBEM EventID: 4894. WBEM ProviderName: FPL_IndicationProvider 10565 Warning Error setting up XBC-XBC link for routing across it. Probable Cause: System Firmware was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to troubleshoot the fabric and/or backplane subsystem. WBEM EventID: 4899. WBEM ProviderName: FPL_IndicationProvider Platform Events 79