HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 49
Data read from the CC Error Mask CSR. Probable Cause: CC to XBC link init failure.
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Event ID Event Severity Event Description 8147 Error Boot is disabled because the cell type does not match the System FW ROM type. Probable Cause: The cell's installed CPU modules do not all have the same type, frequency and partition compatibility, so the Cell type cannot be accurately determined. Recommended Action: Contact HP support personnel to troubleshoot the mismatched CPU module WBEM EventID: 712. WBEM ProviderName: FPL_IndicationProvider 8149 Warning The PDHC has waited an abnormally long time for PDH bus access. Probable Cause: A hardware fault is preventing the PDH arbiter from granting the PDHC control of the bus. Recommended Action: Contact HP support personnel to troubleshoot the cell board and/or PDH daughtercard. WBEM EventID: 713. WBEM ProviderName: FPL_IndicationProvider 8151 Warning The PDHC has waited an abnormally long time to obtain the PDH semaphore. Probable Cause: A hardware fault is preventing the PDH bus semaphore from being taken/released as expected. Recommended Action: Contact HP support personnel to troubleshoot the Cell Board and/or PDH Daughtercard WBEM EventID: 714. WBEM ProviderName: FPL_IndicationProvider 8153 Warning An error occurred while transmitting an IPMI message in the BMC2HOST direction. Probable Cause: A hardware fault is preventing the BMC2HOST queue from working. Recommended Action: Contact HP support personnel to troubleshoot the PDH Daughtercard. WBEM EventID: 715. WBEM ProviderName: FPL_IndicationProvider 8154 Warning EFI unable to read initial debug level from the BMC. Probable Cause: SAL service to read tokens not functioning properly. Recommended Action: Reset the system. Clear SFW NVM. Upgrade system firmware. WBEM EventID: 716. WBEM ProviderName: FPL_IndicationProvider 8156 Error A XBC port was unexpectedly found to not be landmined. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane WBEM EventID: 717. WBEM ProviderName: FPL_IndicationProvider 8159 Error An invalid number of XBC ports were landmined in the system. Probable Cause: Hardware failure: link, crossbar chip, or cell. Recommended Action: Check for hardware failures. Reset backplane to re-initialize fabric. WBEM EventID: 1033. WBEM ProviderName: FPL_IndicationProvider 8184 Error The backplane was not recognized as one that contains fabric. Probable Cause: An unrecognized backplane is installed. Recommended Action: Contact HP Support Personnel to determine why the backplane was unrecognized. WBEM EventID: 719. WBEM ProviderName: FPL_IndicationProvider 8186 Warning Writing the XIN Error Mask Register to zero failed. Probable Cause: CC Write Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 720. WBEM ProviderName: FPL_IndicationProvider 8187 Error Dumping error info. Read status of the Primary Mode Register. Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link WBEM EventID: 1758. WBEM ProviderName: FPL_IndicationProvider 8188 Error Data read from the CC Primary Mode CSR. Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link WBEM EventID: 722. WBEM ProviderName: FPL_IndicationProvider 8189 Error Dumping error info. Read status of the CC Error Mask Register. Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link WBEM EventID: 723. WBEM ProviderName: FPL_IndicationProvider 8190 Error Data read from the CC Error Mask CSR. Probable Cause: CC to XBC link init failure. Contact your HP service representative to check the CC to XBC link WBEM EventID: 724. WBEM ProviderName: FPL_IndicationProvider 8194 Warning The link could not be crossed upon first attempt. Probable Cause: The neighbor port is not routable. The port is either: not connected, landmined, in FE, or contains an SBE or LPE. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 725. WBEM ProviderName: FPL_IndicationProvider Platform Events 49