IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
Event ID Event Severity Event Description 11569 Error IO Backplane +12V power fault. Probable Cause: One of the +12v VRM's is reporting a fault. One failure and power state is N, after two power state will be N-. Recommended Action: Check IO backplane power board. Faulted VRM is given by PS command. WBEM EventID: 6828. WBEM ProviderName: FPL_IndicationProvider 11575 Error IO Backplane 1.5V temperature fault. Probable Cause: One of the 1.5v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6829. WBEM ProviderName: FPL_IndicationProvider 11576 Error IO Backplane 3.3V temperature fault. Probable Cause: One of the 3.3v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6830. WBEM ProviderName: FPL_IndicationProvider 11578 Error IO Backplane -12.0V temperature fault. Probable Cause: One of the -12v VRM's is over temp. Recommended Action: Check IO backplane power board faulted VRM is give by PS command. WBEM EventID: 6831. WBEM ProviderName: FPL_IndicationProvider 11579 Error IO Backplane +12.0V temperature fault. Probable Cause: One of the +12v VRM's is over temp and has shutdown. One failure and the Redundancy state is 'not redundant', after two power faults the redundancy state is 'insufficient'. Recommended Action: Check IO backplane power board. Faulted VRM is given by PS command. WBEM EventID: 6832. WBEM ProviderName: FPL_IndicationProvider 11580 Warning The local cell was unable to clear the link_off bit on at least one CC-CC link. Data field: return value of Phase3BackToBackPrep(). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4944. WBEM ProviderName: FPL_IndicationProvider 11581 Warning ArfOLAPreRendez() was unable to reach the added cell. Data field: bitmap of unreachable cells. Probable Cause: Firmware was unable to find a valid route to a cell being added by OLA. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4945. WBEM ProviderName: FPL_IndicationProvider 11582 Warning An unexpected error occurred in SetupNCTable(). Data field: return value from SetupNCTable(). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4946. WBEM ProviderName: FPL_IndicationProvider 11583 Warning Phase4BackToBackPrep() unexpectedly failed. Data field: return value of Phase4BackToBackPrep(). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4947. WBEM ProviderName: FPL_IndicationProvider 11584 Warning Unable to synch graphs between all cells in the partition after an OLA. Data field: (master cell number 56) | (bitmap of cells to synch). Probable Cause: An error occurred while routing the fabric Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4948. WBEM ProviderName: FPL_IndicationProvider 11585 Warning Data field: bitmap of unreachable cells. Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4949. WBEM ProviderName: FPL_IndicationProvider 11586 Warning An unexpected error occurred while setting up the Non-Coherent or Coherent tables after an OLA. Data field: return value from SetupNCTable() or SetupCohTable(). Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 4950. WBEM ProviderName: FPL_IndicationProvider Platform Events 89