HP ML530 ProLiant ML530 Generation 2 Server Setup and Installation Guide - Page 152
Marking the Rear of the Rack with the Rack Template
UPC - 720591250669
View all HP ML530 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Installing the Rack Server 3. Secure the template against the front of the rack by pressing the two push tabs through the matching holes. Figure 5-1: Measuring with the rack template on the front of the rack 4. Use a pencil to mark the locations on the outside of the front of the rack where the rack rails must be inserted (designated "R" on the template). Also mark the locations for the cage nuts (designated "C" on the template). 5. Place additional pencil marks on the rack at the top edge of the template to align the template for the next component. Marking the Rear of the Rack with the Rack Template To mark the rear of the rack with the rack template: 1. Move to the rear of the rack and turn the template over to use the reverse side of the template. 2. Starting at the bottom of the rack, or at the top of a previously mounted component, match the hole pattern on the template with the holes on the vertical posts of the rack. NOTE: Tick marks on the rack's vertical posts mark off U-spaces in the rack configuration and help to maintain the proper alignment. HP ProLiant ML530 Generation 2 Server Setup and Installation Guide 5-5