Hot-plug power supplies, rack configuration, Table 3-10
UPC - 720591250669
View all HP ML530 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
Installing Hardware Options The ProLiant ML530 Generation 2 server ships with one hot-plug power supply. The following procedures show you how to install an optional hot-plug power supply for redundancy. To install the redundant hot-plug power supply: 1. Locate the power supply blank at the rear of the server beneath the system tray. Figure 3-37: Hot-plug power supplies (rack configuration) Table 3-10: Hot-Plug Power Supply Locations Item Power Supply 1 Hot-plug power supply 1 2 Hot-plug power supply bay 2 (redundant) 3 Hot-plug power supply bay 3 (not used)* *Improved power supply performance ensures that a single power supply provides sufficient power to the entire system. Complete redundancy can be achieved by installing only one additional power supply. 2. Locate and remove the Torx T-15 tool. See "Locating and Removing the Torx T-15 Tool" in this chapter. HP ProLiant ML530 Generation 2 Server Setup and Installation Guide 3-47