HP ML530 ProLiant ML530 Generation 2 Server Setup and Installation Guide - Page 250
Table C-11, Hot-Plug SCSI Hard Drive LED Combinations
UPC - 720591250669
View all HP ML530 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 250 highlights
System LEDs and Switches Table C-11: Hot-Plug SCSI Hard Drive LED Combinations Activity LED On On Flashing Off Online LED Off Flashing Flashing Off Fault LED Off Off Flashing Off State Do not remove the drive. Removing a drive during this process causes data loss. The drive is being accessed and is not configured as part of an array. Do not remove the drive. Removing a drive during this process causes data loss. The drive is rebuilding or undergoing capacity expansion. Do not remove the drive. Removing a drive during this process causes data loss. The drive is part of an array being selected by the Array Configuration Utility. -Or- The Options ROMPaq is upgrading the drive. OK to replace the drive online if a predictive failure alert is received and the drive is attached to an array controller. The drive is not configured as part of an array. -Or- If this drive is part of an array, a powered-on controller is not accessing the drive. -Or- The drive is configured as an online spare. continued C-16 HP ProLiant ML530 Generation 2 Server Setup and Installation Guide