HP ML530 ProLiant ML530 Generation 2 Server Setup and Installation Guide - Page 274
Table E-1, Server Specifications, Feature, Units
UPC - 720591250669
View all HP ML530 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 274 highlights
Server Specifications Table E-1: Server Specifications Feature Dimensions Height (without casters) Depth (without bezel) Width Weight Input requirements Rated input voltage Rated input frequency Rated input current Rated input power BTUs per hour Power supply output Rated steady-state power Maximum peak power Temperature range Operating Shipping Relative humidity (non-condensing) Operating Non-operating Wet bulb temperature Heat dissipation Units 51.5 cm (20.3 in) 69.7 cm (27.5 in) 32.6 cm (12.9 in) 45.4 kg (100 lb) to 66.2 kg (146 lb) 100-127 VAC 200-240 VAC 47-63 Hz 10A for 100-127 VAC 4.8A for 200-240 VAC 1000W for 100-127 VAC 960W for 200-240 VAC 3415 BTUs/hr 100-127 VAC 3015 BTUs/hr 200-240 VAC Rated steady-state power: 600 W Maximum peak power: 600 W 10° to 35°C (50° to 95°F) -30° to 60°C (-20° to 140°F) 20% to 80% 5% to 90% 38.7°C (101.7°F) 2400 BTUs/hr maximum E-2 HP ProLiant ML530 Generation 2 Server Setup and Installation Guide