HP Surestore 28/48-Slot with DLT7000 Digital Linear Tape SCSI-2 Drive and SCSI - Page 173

Log Sense Command 4DH

Page 173 highlights

Library SCSI-3 Command Set Log Sense Command (4DH) Table 2-105 Tape Drive/ Library Flag Definitions No Flag Type Displayed Message Probable Cause 6 Library C Interface 9 Library C Humidity Limits 13 Library W Pick Retry The library has a problem with the host interface: 1. Check the cables, cable connections, and terminators. 2. Restart the operation. The library has identified an interfacing fault. This flag is set when the changer has detected a problem with the SCSI interface, but has continued to function. RTL error exit will continue. General environmental conditions inside the library are outside the specified humidty range. 1. Stop changer operation. 2. Correct the environment by raising or lowering humidity levels as needed. 3. Restart the operation. Library humidity limits exceeded. The humidity is either too low or too high for proper changer operations. There is a potential problem with a drive ejecting cartridges short or with the library mechanism picking a cartridge from a slot. 1. No action needs to be taken at this time. 2. If the problem persists, call tape drive support. Operation to pick a cartridge from a slot had to perform an excessive number of retries before succeeding. This flag is set anytime the changer had to retry a picker operation from a drive or slot. Chapter 2 2- 129

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302

Chapter 2
2-129
Library SCSI-3 Command Set
Log Sense Command (4DH)
6
Library
Interface
C
The library has a problem with the
host interface:
1. Check the cables, cable
connections, and terminators.
2. Restart the operation.
The library has
identified an
interfacing fault.
This flag is set when
the changer has
detected a problem
with the SCSI
interface, but has
continued to
function. RTL error
exit will continue.
9
Library
Humidity
Limits
C
General environmental conditions
inside the library are outside the
specified humidty range.
1. Stop changer operation.
2. Correct the environment by
raising or lowering humidity levels
as needed.
3. Restart the operation.
Library humidity
limits exceeded. The
humidity is either too
low or too high for
proper changer
operations.
13
Library
Pick Retry
W
There is a potential problem with a
drive ejecting cartridges short or
with the library mechanism picking
a cartridge from a slot.
1. No action needs to be taken at
this time.
2. If the problem persists, call tape
drive support.
Operation to pick a
cartridge from a slot
had to perform an
excessive number of
retries before
succeeding. This flag
is set anytime the
changer had to retry
a picker operation
from a drive or slot.
Table 2-105
Tape Drive/ Library Flag Definitions
No
Flag
Type
Displayed Message
Probable Cause