HP Surestore 28/48-Slot with DLT7000 Digital Linear Tape SCSI-2 Drive and SCSI - Page 173
Log Sense Command 4DH
View all HP Surestore 28/48-Slot with DLT7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 173 highlights
Library SCSI-3 Command Set Log Sense Command (4DH) Table 2-105 Tape Drive/ Library Flag Definitions No Flag Type Displayed Message Probable Cause 6 Library C Interface 9 Library C Humidity Limits 13 Library W Pick Retry The library has a problem with the host interface: 1. Check the cables, cable connections, and terminators. 2. Restart the operation. The library has identified an interfacing fault. This flag is set when the changer has detected a problem with the SCSI interface, but has continued to function. RTL error exit will continue. General environmental conditions inside the library are outside the specified humidty range. 1. Stop changer operation. 2. Correct the environment by raising or lowering humidity levels as needed. 3. Restart the operation. Library humidity limits exceeded. The humidity is either too low or too high for proper changer operations. There is a potential problem with a drive ejecting cartridges short or with the library mechanism picking a cartridge from a slot. 1. No action needs to be taken at this time. 2. If the problem persists, call tape drive support. Operation to pick a cartridge from a slot had to perform an excessive number of retries before succeeding. This flag is set anytime the changer had to retry a picker operation from a drive or slot. Chapter 2 2- 129