JVC KY-F70BU Instruction Manual - Page 59
FREEZE screen, PROCESS 1/3 screen
View all JVC KY-F70BU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
FREEZE screen Menu item CANCEL Function/variable range Default value Used to set the cancellation method of freeze. MANUAL: freeze is cancelled by pressing the FREEZE button. AUTO: freeze is automatically cancelled. (1s) The figures in parentheses denote the approxi- (3s) mate time (sec) until automatic release. (5s) Pressing the FREEZE button before automati- cally cancel will repeat the freeze. MANUAL PROCESS (1/3) screen Menu item DETAIL LEVEL LEVEL DEP Function/variable range Used to set whether to emphasize details. ADJUST: changes the detail emphasis OFF: no detail emphasis Default value ADJUST The emphasis level of the detail is adjusted when DETAIL 0 is set to ADJUST. Sharpen the detail: increase the number Soften the detail: decease the number [Variable range: -7 ~ 7] Adjusted when you want to reduce noise in black areas. Noise in black areas is reduced because the frequency characteristics of areas where the image signal level falls below this set value are lowered. However, fine details in areas falling below the set value will be lost. [Variable range when ON: 0.0% ~ 28.5% (changeable in 0.5 steps)] 0.0% MEMO The setting value is the value to be set for the input signal level before GAMMA compensation. E55