LG 42CQ610H Setup Guide - Page 20

Installer Menu Cont.

Page 20 highlights

Installer Menu (Cont.) Installer Menu Items 000 through 070 Menu Item 000 001 002 003 Function INSTALLER SEQ POWER MANAGE AC ON BAND/AFC Value Range 0 ~ 3 0 ~ 7 0 / 1 0 ~ 3 004 STRT CHANNEL 0 ~ 127, 255 005 CHAN LOCK 0 / 1 007 STRT VOLUME 0 ~ 63, 255 008 MIN VOLUME 009 MAX VOLUME 010 MUTE DISABLE 011 KEY DEFEAT 012 IR BANKS EN. 013 SCAN MODE 014 STRT CH IN SM 015 SLEEP TIMER 016 EN TIMER 017 ALARM 020 FEATURE LEVEL 021 V-CHIP 022 MAX BLK HRS 023 CAPTION LOCK 0 ~ 63 0 ~ 63 0 / 1 0 / 1 0 / 1 0 / 1 0 / 1 0 / 1 0 / 1 0 / 1 0 ~ 1, 16 ~ 24, 64 ~ 65 0 / 1 0 ~ 99 0 / 1 025 FUNCTION PRE. 0 ~ 1 027 HOSPITAL MODE 028 CH. OVERIDE 029 OLD OCV 030 ACK MASK 031 POLL RATE 032 TIMING PULSE 035 COMPPORT EN. 039 REAR AUX EN 046 STRT AUX SRCE 047 AUX STATUS 053 DIS. CH-TIME 069 EN. CH-T COL. 070 FOR. CH-TIME 0 ~ 162, 254 0 / 1 0 / 1 0 / 1 20 ~ 169 186 ~ 227 0 / 1 0 / 1 1, 3 ~ 5, 255 0 / 1 0 / 1 0 / 1 0 ~ 7 Default Value Brief Description of Function 0 Leave default set to 0. 0 Sets number of hours of no activity before automatic shutoff. 0 Set to 1 to enable Auto Turn ON when AC power is applied. 1 Selects Tuning Band: 0=Broadcast, 1=CATV, 2=HRC, 3=IRC 255 Channel tuned when TV is turned ON. (Set to 255 to tune to channel tuned before TV turned OFF.) 0 If set to 1, cannot tune from current channel. 255 Volume level when TV is turned ON. (Set to 255 to use volume level before TV turned OFF.) 0 Sets minimum allowable volume setting. 63 Sets maximum allowable volume setting. 0 Set to 1 to disable Mute Function. 1 Set to 1 to disable menu navigation keys on display panel. 0 Set to 1 to enable TV to respond to bank discrete IR codes. 1 Set to 1 to allow Channel Up/Down to turn ON TV. (See detailed descriptions.) 0 Set to 1 to use the Start Channel for the Channel Map pivot point in Scan Mode. 1 Set to 1 to enable Sleep Timer. 1 Set to 1 to enable On/Off Timers. 1 Set to 1 to enable Alarm. 1 Determines an additional IR code scheme to which the TV will respond. 1 Set to 1 to enable V-Chip (Parental Control) functions. 12 Sets number of V-Chip blocking hours. 0 Set to 1 to retain caption setting before TV turned Off. 1 Set to 1 to allow Channel Preview/Banks Setup Menu access via CH PREVIEW key on Installer Remote. 254 Set according to the speaker selection, the pillow speaker code/supply voltage, and the hospital IR code. See detailed instructions. 1 If set to 0, limits direct access to favorite channels. 0 Set to 1 to change MPI operation to OCV. 0 If set to 1, enables ACK feature of MPI. 94 Selects poll rate for MPI. 207 Sets baud rate for MPI. 1 Set to 0 to disable HDMI 1. Set to 1 enable HDMI 1. 1 Set to 1 to enable display panel Video 1 input jack. 255 Sets the starting Aux source (if item 004 STRT CHANNEL is set to 0). 0 Set to 1 for MPI Aux source to be reported as a channel number instead of Channel 0. 0 Set to 1 to disable Channel-Time display. 1 Set to 1 to enable custom color for the Channel-Time display. 2 Chooses custom foreground color for the Channel-Time display. 20 206-4207

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

20
206-4207
Menu
Item
Function
Value Range
Default Value
Brief Description of Function
000
INSTALLER SEQ
0 ~ 3
0
Leave default set to 0.
001
POWER MANAGE
0 ~ 7
0
Sets number of hours of no activity before automatic shutoff.
002
AC ON
0 / 1
0
Set to 1 to enable Auto Turn ON when AC power is applied.
003
BAND/AFC
0 ~ 3
1
Selects Tuning Band: 0=Broadcast, 1=CATV, 2=HRC, 3=IRC
004
STRT CHANNEL
0 ~ 127, 255
255
Channel tuned when TV is turned ON. (Set to 255 to tune to channel tuned
before TV turned OFF.)
005
CHAN LOCK
0 / 1
0
If set to 1, cannot tune from current channel.
007
STRT VOLUME
0 ~ 63, 255
255
Volume level when TV is turned ON. (Set to 255 to use volume level
before TV turned OFF.)
008
MIN VOLUME
0 ~ 63
0
Sets minimum allowable volume setting.
009
MAX VOLUME
0 ~ 63
63
Sets maximum allowable volume setting.
010
MUTE DISABLE
0 / 1
0
Set to 1 to disable Mute Function.
011
KEY DEFEAT
0 / 1
1
Set to 1 to disable menu navigation keys on display panel.
012
IR BANKS EN.
0 / 1
0
Set to 1 to enable TV to respond to bank discrete IR codes.
013
SCAN MODE
0 / 1
1
Set to 1 to allow Channel Up/Down to turn ON TV. (See detailed descriptions.)
014
STRT CH IN SM
0 / 1
0
Set to 1 to use the Start Channel for the Channel Map pivot point in Scan Mode.
015
SLEEP TIMER
0 / 1
1
Set to 1 to enable Sleep Timer.
016
EN TIMER
0 / 1
1
Set to 1 to enable On/Off Timers.
017
ALARM
0 / 1
1
Set to 1 to enable Alarm.
020
FEATURE LEVEL
0 ~ 1, 16 ~ 24,
64 ~ 65
1
Determines an additional IR code scheme to which the TV will respond.
021
V-CHIP
0 / 1
1
Set to 1 to enable V-Chip (Parental Control) functions.
022
MAX BLK HRS
0 ~ 99
12
Sets number of V-Chip blocking hours.
023
CAPTION LOCK
0 / 1
0
Set to 1 to retain caption setting before TV turned Off.
025
FUNCTION PRE.
0 ~ 1
1
Set to 1 to allow Channel Preview/Banks Setup Menu access via CH
PREVIEW key on Installer Remote.
027
HOSPITAL MODE
0 ~ 162, 254
254
Set according to the speaker selection, the pillow speaker code/supply voltage,
and the hospital IR code. See detailed instructions.
028
CH. OVERIDE
0 / 1
1
If set to 0, limits direct access to favorite channels.
029
OLD OCV
0 / 1
0
Set to 1 to change MPI operation to OCV.
030
ACK MASK
0 / 1
0
If set to 1, enables ACK feature of MPI.
031
POLL RATE
20 ~ 169
94
Selects poll rate for MPI.
032
TIMING PULSE
186 ~ 227
207
Sets baud rate for MPI.
035
COMPPORT EN.
0 / 1
1
Set to 0 to disable HDMI 1. Set to 1 enable HDMI 1.
039
REAR AUX EN
0 / 1
1
Set to 1 to enable display panel Video 1 input jack.
046
STRT AUX SRCE
1, 3 ~ 5, 255
255
Sets the starting Aux source (if item 004 STRT CHANNEL is set to 0).
047
AUX STATUS
0 / 1
0
Set to 1 for MPI Aux source to be reported as a channel number instead of
Channel 0.
053
DIS. CH-TIME
0 / 1
0
Set to 1 to disable Channel-Time display.
069
EN. CH-T COL.
0 / 1
1
Set to 1 to enable custom color for the Channel-Time display.
070
FOR. CH-TIME
0 ~ 7
2
Chooses custom foreground color for the Channel-Time display.
Installer Menu Items 000 through 070