Lenovo ThinkCentre M50 Hardware Maintenance Manual (HMM) - Page 102
Diagnostics
View all Lenovo ThinkCentre M50 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
POST Error Code FRU/Action 662 Configuration Change has occurred Diskette drive configuration error or wrong diskette drive type; run Setup. 6XX Not listed above 1. Diskette Drive 2. System Board 3. Riser card 4. External Drive Adapter 5. Diskette Drive Cable 6. Power Supply 762 Math coprocessor configuration error 1. Run Setup. 2. Processor 3. System Board 7XX Not listed above 1. Processor 2. System Board 962 Parallel port configuration error 1. Run Setup. 2. Parallel Adapter (if installed) 3. System Board 9XX 1. Printer 2. System Board 1047 16-Bit AT™ Fast SCSI Adapter 107X Check SCSI terminator installation 1. Check SCSI terminator installation 2. SCSI Cable 3. SCSI Terminator 4. SCSI Device 5. SCSI Adapter 1101 Run Enhanced Diagnostics Serial connector error, possible system board failure 1101, 1102, 1106, 1108, 1109 1. System Board 2. Any Serial Device 1107 1. Communications Cable 2. System Board 1102 Card selected feedback error Run Enhanced Diagnostics 1103 Port fails register check 1. Run Enhanced Diagnostics 2. System Board 1106 Serial option cannot be turned off 1. Run Enhanced Diagnostics 2. System Board 1107 1. Serial Device Cable 2. System Board 1110 Register test failed 1. Run Enhanced Diagnostics 2. System Board 1116 Interrupt error Run Enhanced Diagnostics 96 Hardware Maintenance Manual