POST Error Code FRU/Action 1117 Failed baud rate test Run Enhanced Diagnostics 1162 Serial port configuration error 1. Run Setup. 2. Serial Adapter (if installed) 3. System Board 11XX Not listed above System Board 1201 1. System Board 2. Any Serial Device 1202, 1206, 1208, 1209, 12XX 1. Dual Async Adapter/A 2. System Board 3. Any Serial Device 1207 1. Communications Cable 2. Dual Async Adapter/A 13XX Game Adapter 1402 Printer not ready Information only 1403 No paper error, or interrupt failure Information only 1404 System board timeout failure Run Enhanced Diagnostics 1405 Parallel adapter error Run Enhanced Diagnostics 1406 Presence test error Run Enhanced Diagnostics 14XX Not listed above. Check printer before replacing system board 1. Printer 2. System Board 15XX SDLC Adapter 1692 Boot sequence error Run FDISK to ensure at least one active partition is set active 16XX 36/38 Workstation Adapter 1762 Hard disk drive configuration error Run Setup. (See Chapter 5, "IBM Setup Utility program," on page 19.) 1780 (Disk Drive 0) 1781 (Disk Drive 1) 1782 (Disk Drive 2) 1783 (Disk Drive 3) 1. Hard Disk Drive 2. System Board 3. Riser card 4. Hard Disk Cable 5. Power Supply 1800 PCI/PnP Error! No Hardware Interrupt 1. Run Setup and verify PCI/ISA Available configuration settings. 2. Rerun diagnostics. 3. PCI Adapter Chapter 7. Symptom-to-FRU Index 97