Lenovo ThinkCentre M50 Hardware Maintenance Manual (HMM) - Page 107
Error, FRU/Action, 101XX, Modem, Adapter/A, Enhanced, Diagnostics, Drive, Check, Configuration
View all Lenovo ThinkCentre M50 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
POST Error Code 101XX Not listed above 10450, 10451, 10490, 10491, 10492, 10499 Read/write error 10452 Seek test error 10453 Wrong drive type? 10454 Sector buffer test error 10455, 10456 Controller error 10459 Drive diagnostic command error 10461 Drive format error 10462 Controller seek error 10464 Hard Drive read error 10467 Drive non-fatal seek error 10468 Drive fatal seek error 10469 Drive soft error count exceeded 10470, 10471, 10472 Controller wrap error 10473 Corrupt data. Low level format might be required 10480 10481 ESDI drive D seek error 10482 Drive select acknowledgement bad 106X1 FRU/Action 1. Modem Adapter/A 2. Data/Fax Modem 3. System Board 4. Riser card 1. Run Enhanced Diagnostics 2. Hard Disk Drive 3. System Board 4. Riser card Run Enhanced Diagnostics Information only Run Enhanced Diagnostics Run Enhanced Diagnostics Information only Run Enhanced Diagnostics Run Enhanced Diagnostics Run Enhanced Diagnostics Run Enhanced Diagnostics Run Enhanced Diagnostics Run Enhanced Diagnostics Run Enhanced Diagnostics Information only 1. Hard Disk Drive (ESDI) 2. Drive Cable 3. System Board Run Enhanced Diagnostics Run Enhanced Diagnostics 1. Check Configuration 2. Ethernet Adapter Chapter 7. Symptom-to-FRU Index 101