Lexmark C520 Service Manual - Page 88
Hardware Tests
View all Lexmark C520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Hardware Tests Panel Test This test verifies the operator panel LCD function. To run the Panel Test: 1. Select HARDWARE TESTS from DIAGNOSTICS. 2. Select Panel Test. The Panel Test continually executes. 3. Press Stop ( ) to cancel the test. Button Test This test verifies the operator panel button function. To run the Button Test: 1. Select Button Test from HARDWARE TESTS in the Diagnostics mode. Button Test 5022-xxx 2. Press each button one at a time, and an X appears in the box that represents that button. When you press Back ( ) or Stop ( ), the test ends. Press Back or Stop to cancel the test. DRAM Test This test checks the validity of DRAM, both standard and optional. The test writes patterns of data to DRAM to verify that each bit in memory can be set and read correctly. To run the DRAM Test: Select DRAM Test from HARDWARE TESTS in DIAGNOSTICS. The power indicator blinks indicating the test is in progress. Note: Turn off the printer to exit the test before the test is complete. DRAM Test P:###### 128M F:##### P:###### represents the number of times the memory test has passed and finished successfully. Initially, 000000 displays with the maximum pass count being 99,999. F:##### represents the number of times the memory test has failed and finished with errors. Initially, 00000 displays with the maximum fail count being 99,999. Once the maximum pass count or fail count is reached, the test is stopped, the power indicator turns on solid, and the final results appear. If the test fails, SDRAM Error appears for approximately three seconds and the failure count increases by 1. Diagnostic aids 3-11