Sharp AR-M205 AR-M160 AR-M205 Operation Manual - Page 64

Indicators And Display, Messages - developer replacement

Page 64 highlights

INDICATORS AND DISPLAY MESSAGES If one of the following indicators lights up or one of the following messages appears in the display, check the meaning of the indicator or message in the following table and take appropriate action. Toner cartridge replacement required indicator Developer replacement required indicator Maintenance indicator Display Paper required indicator Misfeed indicator Indication Maintenance indicator Developer replacement required indicator Toner cartridge replacement required indicator Steadily lit Steadily lit Steadily lit Blinking Paper required indicator Steadily lit Misfeed indicator Blinking ORIGINAL SIZE indicator Blinking PAPER SIZE indicator [CH] appears in display Blinking Steadily lit Blinking Letters and numbers appear in the display Cause and solution Service by an authorized SHARP service technician is required. Developer is required. Contact your SHARP service center as soon as possible. Replacement of toner cartridge will be needed soon. Prepare a new cartridge. Toner cartridge must be replaced. Replace it with a new one. The tray is out of paper. Load paper. It is also possible that the tray is not inserted completely into the machine. Make sure it is inserted correctly. A paper misfeed has occurred. Remove the misfeed as explained in "MISFEED REMOVAL". If the ORIGINAL SIZE indicator blinks when margin shift is selected, rotate the original so that it is in the same orientation as the blinking ORIGINAL SIZE indicator. There is no appropriate paper. Load appropriate paper in a paper tray. The front cover or the side cover is open. Close the front cover or the side cover. The toner cartridge is not installed correctly. Reinstall the toner cartridge. If [CH] still blinks in the display after reinstalling the toner cartridge, contact a SHARP service center. Write down the code that appears and then unplug the power cord and contact your dealer. Tell your dealer what code appeared and the circumstances under which it appeared. "FUL" appears in the display Data is being held in memory. Print the data or clear it from memory. When "Use close paper size" is disabled ORIGINAL PAPER SIZE SIZE 11X17 8½X14 8½X11 8½X5½ 8½X11 EXTRA Misfeed location indicator lights up at the optional 2 x 250-sheet/250-sheet paper feed unit The PAPER SIZE indicator on the operation panel will blink. You can press the [TRAY SELECT] key ( ) to select a tray manually, or load paper in the bypass tray and press the [ON LINE] key ( ) to begin printing. The lower side cover of the 2 x 250-sheet/250-sheet paper feed unit is open. Close the lower side cover. Page - - - 70 14 63 36 13 - 70 - 33, 35 Online manual - 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

62
INDICATORS AND DISPLAY
MESSAGES
If one of the following indicators lights up or one of the following messages appears in the display, check the
meaning of the indicator or message in the following table and take appropriate action.
Indication
Cause and solution
Page
Maintenance
indicator
Steadily
lit
Service by an authorized SHARP service technician is
required.
Developer
replacement
required indicator
Steadily
lit
Developer is required. Contact your SHARP service center
as soon as possible.
Toner cartridge
replacement
required indicator
Steadily
lit
Replacement of toner cartridge will be needed soon.
Prepare a new cartridge.
Blinking
Toner cartridge must be replaced. Replace it with a new one.
70
Paper required
indicator
Steadily
lit
The tray is out of paper. Load paper. It is also possible that
the tray is not inserted completely into the machine. Make
sure it is inserted correctly.
14
Misfeed indicator
Blinking
A paper misfeed has occurred. Remove the misfeed as
explained in "MISFEED REMOVAL".
63
ORIGINAL SIZE indicator
Blinking
If the ORIGINAL SIZE indicator blinks when margin shift is
selected, rotate the original so that it is in the same
orientation as the blinking ORIGINAL SIZE indicator.
36
PAPER SIZE indicator
Blinking
There is no appropriate paper. Load appropriate paper in a
paper tray.
13
[CH] appears in display
Steadily
lit
The front cover or the side cover is open. Close the front
cover or the side cover.
Blinking
The toner cartridge is not installed correctly. Reinstall the toner
cartridge. If [CH] still blinks in the display after reinstalling the
toner cartridge, contact a SHARP service center.
70
Letters and numbers appear
in the display
Write down the code that appears and then unplug the
power cord and contact your dealer. Tell your dealer what
code appeared and the circumstances under which it
appeared.
"FUL" appears in the display
Data is being held in memory. Print the data or clear it from
memory.
33, 35
When "Use close paper size" is
disabled
The PAPER SIZE indicator on the operation panel will blink.
You can press the [TRAY SELECT] key (
) to select a tray
manually, or load paper in the bypass tray and press the
[ON LINE] key (
) to begin printing.
Online
manual
Misfeed location indicator lights up at
the optional 2 x 250-sheet/250-sheet
paper feed unit
The lower side cover of the 2 x 250-sheet/250-sheet paper
feed unit is open. Close the lower side cover.
Misfeed indicator
Paper required
indicator
Maintenance
indicator
Toner cartridge replacement required indicator
Developer replacement required indicator
Display
ORIGINAL
SIZE
PAPER
SIZE
11
X
17
X
14
X
11
X
11
X
EXTRA