Sony BVM-HX3110 Operating Instructions - Page 41

Monitoring Tool menu

Page 41 highlights

Monitoring Tool menu The monitoring function for the input video signal and recording assistance function are configured. Scopes Submenu Vector Scope Setting Sets whether to display Vector Scope (vector scope). Select "On" to display the color difference components of the video signal as vectors. Red Magenta Yellow Black Blue Submenu Display WFM Setting Sets whether to display WFM (Wave Form Monitor). Select "On" to display the waveform. Signal level (%) Waveform Signal tone or brightness 1) Green Cyan Color target frame (The outer frame indicates 100 %, and the inner frame indicates 75 %.) CGS Sets whether to display CGS (Color Gamut Scope). Select "On" to map the video signal to x and y coordinates. Type of the waveform 1) The signal tone is displayed when EOTF is set to 2.2, 2.4, 2.6, CRT, or 2.4(HDR). The brightness of the input signal is displayed when EOTF is set to SMPTE ST 2084. When it is set to ITU-R BT.2100(HLG), the brightness of the input signal corresponding to the brightness of the monitor is displayed. The brightness is calculated from the default value of the System Gamma (page 25), and the display of the scale does not change even if you change the System Gamma settings. When EOTF is set to S-Log3 or S-Log3(Live HDR), the brightness for input signals defined in SR Live for HDR workflow is displayed. Different triangles based on the color spaces are displayed on the CIE1931 xy chromaticity diagram. Color space settings  ITU-R BT.709/EBU/SMPTE-C: A triangle indicating the chromaticity range of ITU-R BT.709 is displayed.  ITU-R BT.2020: Triangles (chromaticity range) indicating ITU-R BT.709, DCI-P3, and ITU-R BT.2020 are displayed in ascending order of size.  S-Gamut/S-Gamut3: Triangles (chromaticity range) indicating ITU-R BT.709, DCI-P3, and S-Gamut/SGamut3 are displayed in ascending order of size.  S-Gamut3.Cine: Triangles (chromaticity range) indicating ITU-R BT.709, DCI-P3, and S-Gamut3.Cine are displayed in ascending order of size.  DCI-P3: Triangles (chromaticity range) indicating ITU-R BT.709 and DCI-P3 are displayed in ascending order of size. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

41
Monitoring Tool menu
The monitoring function for the input video
signal and recording assistance function are
configured.
Scopes
Submenu
Setting
Display
WFM
Sets whether to display WFM (Wave
Form Monitor). Select “On” to display
the waveform.
1)
The signal tone is displayed when EOTF is set to 2.2, 2.4,
2.6, CRT, or 2.4(HDR). The brightness of the input signal is
displayed when EOTF is set to SMPTE ST 2084. When it is
set to ITU-R BT.2100(HLG), the brightness of the input signal
corresponding to the brightness of the monitor is
displayed. The brightness is calculated from the default
value of the System Gamma (page 25), and the display of
the scale does not change even if you change the System
Gamma settings. When EOTF is set to S-Log3 or S-Log3(Live
HDR), the brightness for input signals defined in SR Live for
HDR workflow is displayed.
Signal level (%)
Waveform
Signal tone or
brightness
1)
Type of the waveform
Vector Scope
Sets whether to display Vector Scope
(vector scope). Select “On” to display
the color difference components of the
video signal as vectors.
CGS
Sets whether to display CGS (Color
Gamut Scope). Select "On" to map the
video signal to x and y coordinates.
Different triangles based on the color spaces are displayed on
the CIE1931 xy chromaticity diagram.
Color space settings
ITU-R BT.709/EBU/SMPTE-C:
A triangle indicating the
chromaticity range of ITU-R BT.709 is displayed.
ITU-R BT.2020:
Triangles (chromaticity range) indicating
ITU-R BT.709, DCI-P3, and ITU-R BT.2020 are displayed
in ascending order of size.
S-Gamut/S-Gamut3:
Triangles (chromaticity range)
indicating ITU-R BT.709, DCI-P3, and S-Gamut/S-
Gamut3 are displayed in ascending order of size.
S-Gamut3.Cine:
Triangles (chromaticity range) indicating
ITU-R BT.709, DCI-P3, and S-Gamut3.Cine are displayed
in ascending order of size.
DCI-P3:
Triangles (chromaticity range) indicating ITU-R
BT.709 and DCI-P3 are displayed in ascending order of
size.
Submenu
Setting
Red
Color target frame (The outer frame
indicates 100 %, and the inner frame
indicates 75 %.)
Magenta
Blue
Cyan
Green
Black
Yellow