Uniden BCT15 English Owners Manual - Page 124

Set Modulation, Set Attenuator, Set Tone, Edit Tone A, Set Delay Time, 5 sec, Infinite, Set Alert

Page 124 highlights

Set Modulation - Set the modulation type for the paging signal. Next choose the modulation setting: Auto - The scanner uses the default modulation for the frequency band. If the default modulation is AM, WFM, or FMB, the modulation operates as FM. FM - The scanner uses FM for the frequency band. This is the default setting. NFM - The scanner uses NFM modulation. Set Attenuator - Turn the Scroll Control to select On or Off. Set Tone - Sets the audio tone frequency for the page. Then choose the Tone setting. Edit Tone A - Set the audio frequency for Tone A Edit Tone B - Set the audio frequency for Tone B Notes: • For two-tone pages, enter a value for A and B. • For one-tone pages using short tones of less than 3.75 seconds, enter the tone value for A, and 0 (zero) for B. • For long-tone pages, such as group pages of more than 3.75 seconds, enter 0 (zero) for A and the tone value for B. Set Delay Time - Sets the time the scanner remains in monitor mode after the scanner receives a page and the carrier drops. 1-5 sec - the scanner resumes standby mode after the carrier drops and the selected time expires. Infinite - you must press [HOLD/RESUME] after a page to resume standby mode. Off - the scanner resumes standby as soon as the carrier drops after a page. Set Alert - Sets the alert the scanner uses when it receives an alert. Alert 1 - 9 - scroll to select the alert tone pattern, The scanner sounds each alert as you scroll to its numbered value Off - the scanner does not sound an alert. After you select an alert pattern, the scanner prompts for the alert level for a received alert. Level options 1 to 15 sets a fixed audio level independent of the main volume setting. AUTO uses the main volume setting for the alerts. 124

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

124
Set Modulation
— Set the modulation type for the paging signal. Next choose
the modulation setting:
Auto
— The scanner uses the default modulation for the frequency band. If the
default modulation is AM, WFM, or FMB, the modulation operates as FM.
FM
— The scanner uses FM for the frequency band. This is the default setting.
NFM
— The scanner uses NFM modulation.
Set Attenuator
— Turn the Scroll Control to select
On
or
Off
.
Set Tone
— Sets the audio tone frequency for the page. Then choose the Tone
setting.
Edit Tone A
— Set the audio frequency for Tone A
Edit Tone B
— Set the audio frequency for Tone B
Notes:
For two-tone pages, enter a value for A and B.
For one-tone pages using short tones of less than 3.75 seconds, enter the tone
value for A, and 0 (zero) for B.
For long-tone pages, such as group pages of more than 3.75 seconds, enter 0
(zero) for A and the tone value for B.
Set Delay Time
— Sets the time the scanner remains in monitor mode after the
scanner receives a page and the carrier drops.
1-5 sec
— the scanner resumes standby mode after the carrier drops and the
selected time expires.
Infinite
— you must press
[HOLD/RESUME]
after a page to resume standby
mode.
Off
— the scanner resumes standby as soon as the carrier drops after a page.
Set Alert
— Sets the alert the scanner uses when it receives an alert
.
Alert 1
-
9
— scroll to select the alert tone pattern, The scanner sounds each
alert as you scroll to its numbered value
Off
— the scanner does not sound an alert.
After you select an alert pattern, the scanner prompts for the alert level for a
received alert. Level options 1 to 15 sets a fixed audio level independent of the
main volume setting.
AUTO
uses the main volume setting for the alerts.