Uniden BCT15 English Owners Manual - Page 125
Tone-Out Multi-Channel Monitoring, Setting Tone-Out Record, Scroll, Control
View all Uniden BCT15 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
Tone-Out Multi-Channel Monitoring The scanner can check multiple tone combination pages for channels whose settings are the same. To achieve this, set the channel to the same frequency, modulation, and attenuation. For example, the scanner checks tone combinations for channel 1 to channel 3 for the following settings. Chan Frequency (MHz) Modulation Attenuator Tone A (Hz) Ch 1 137.0000 Auto (NFM) Off 1000.0 Ch 2 137.0000 Auto (NFM) Off 2200.0 Ch 3 137.0000 Auto (NFM) Off 1500.0 Ch 4 137.0000 NFM Off 1800.0 Ch 5 137.0000 FM Off 2000.0 Ch 6 138.0000 Auto (NFM) Off 1000.0 Tone B (Hz) 2000.0 3200.0 2500.0 2800.0 3000.0 2000.0 Although set to Auto, if the band default is anything other than FM or NFM, modulation will always be FM. If you switch to Tone-Out Standby Mode for Multi-Channel Monitoring, the display switches every 2 seconds to show the frequency it is checking. However, it is, at the same time, checking all frequencies for Tones. If one is detected, it switches to Tone-Out Hold mode. Setting Tone-Out Record As with other functions, you can enable a live recording from the REC jack. Once you choose one of the Tone-Outs between 1 and 10, rotate the Scroll Control to Set Record and press F. Next select either On or Off and press F to set your choice and return to the previous menu. Fire Tone-Out Introduction 125