Uniden BCT15 English Owners Manual - Page 137

If you experience difficulty while in TrunkTracker™ mode, try the following steps., SCAN/SEARCH]

Page 137 highlights

Problem Possible Cause Suggestion Scan won't start. You must press [SCAN/SEARCH] to scan. Press [SCAN/SEARCH]. The squelch might need to be adjusted. Adjust the squelch threshold. See "Turning On the Scanner and Setting the Squelch" on Page 51. One or more channels might be Make sure the channels you want to scan locked out. are not locked out. The antenna might need to be Check the antenna connection. adjusted. Weather scan doesn't The squelch might need to be work. adjusted. Adjust the squelch threshold. See "Turning On the Scanner and Setting the Squelch" on Page 51. The antenna might need to be Check the antenna connection. adjusted. There might not be a NOAA Move to an area with a NOAA weather weather broadcast in your area. broadcast. If you experience difficulty while in TrunkTracker™ mode, try the following steps. Problem Possible Cause Scanner won't track a The system might not be one trunked system. your scanner can scan. Suggestion Change to another system and try scanning that system. The data frequency might be missing. Enter the data frequency. The scanner might need to be changed to a Type I scanner setup. Change to a Type I scanner setup. Review programming Motorola systems on the Uniden website, scanners.uniden.com The system you are trying to scan might be LTR or EDACS. Set the scanner to scan LTR or EDACS systems. Review the LTR and EDACS programming information at scanners.uniden.com No ID's have been programmed. Program one or more ID's or use the ID Search mode. The ID's you have stored are not active. Wait for the ID's to become active or scan another system. Troubleshooting 137

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

137
Troubleshooting
If you experience difficulty while in TrunkTracker™ mode, try the following steps.
Scan won’t start.
You must press
[SCAN/SEARCH]
to scan.
Press
[SCAN/SEARCH]
.
The squelch might need to be
adjusted.
Adjust the squelch threshold. See “Turning
On the Scanner and Setting the Squelch”
on Page 51.
One or more channels might be
locked out.
Make sure the channels you want to scan
are not locked out.
The antenna might need to be
adjusted.
Check the antenna connection.
Weather scan doesn’t
work.
The squelch might need to be
adjusted.
Adjust the squelch threshold. See “Turning
On the Scanner and Setting the Squelch”
on Page 51.
The antenna might need to be
adjusted.
Check the antenna connection.
There might not be a NOAA
weather broadcast in your area.
Move to an area with a NOAA weather
broadcast.
Problem
Possible Cause
Suggestion
Scanner won’t track a
trunked system.
The system might not be one
your scanner can scan.
Change to another system and try
scanning that system.
The data frequency might be
missing.
Enter the data frequency.
The scanner might need to be
changed to a Type I scanner
setup.
Change to a Type I scanner setup. Review
programming Motorola systems on the
Uniden website, scanners.uniden.com
The system you are trying to
scan might be LTR or EDACS.
Set the scanner to scan LTR or EDACS
systems. Review the LTR and EDACS
programming information at
scanners.uniden.com
No ID’s have been
programmed.
Program one or more ID’s or use the ID
Search mode.
The ID’s you have stored are
not active.
Wait for the ID’s to become active or scan
another system.
Problem
Possible Cause
Suggestion