Xerox 3300MFP Service Manual - Page 72
Remark, System, Input Current: Under 4.0 Arms/2.0 Arms But, the status when e-coil
UPC - 095205744415
View all Xerox 3300MFP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Theory of Operation ■ Rated Frequency: 50/60 Hz ■ Frequency Fluctuating range: 47 ~ 63 Hz ■ Input Current: Under 4.0 Arms/2.0 Arms (But, the status when e-coil is off or rated voltage is inputted/outputted) ■ Rated Output Power NO ITEM 1 CHANNEL NAME 2 CONNECTOR PIN 3 Rated Output 4 Max. Output Current 5 Peak Loading Current 6 RIPPLE NOISE Voltage 7 Maximum output 8 Peak output 9 Protection for loading shortage and overflowing current CH1 CH2 Remark +5 V +24.0 V CON 35 V PIN: 11, 13, 15 GND PIN: 12, 14, 16 +5 V ± 5% (4.75-5.25 V) CON 324 V PIN: 3, 5, 7, 9 GND PIN: 4, 6, 8, 10 +24 V ± 10% (21.6-26.4 V) 3 A 4.4 A 3.6 A 5.3 A 1 ms 100 m Vp-p Under 500 m Vp-p 15 W 105.6 W 18 W 127.2 W 1 ms Shut down or Fuse Protection Shut down or Output Voltage Drop ■ Consumption Power NO ITEM 1 Stand-By 2 PRINTING 3 Sleep-Mode System Less than 150 W Less than 400 W Less than 11 W 2-30 Phaser 3300MFP Service Manual