Adaptec 2805 User Manual and Install Guide - Page 150

Environmental Specifications, DC Power Requirements, Current Requirements

Page 150 highlights

Appendix G: Technical Specifications ● 149 Environmental Specifications Note: Adaptec RAID controllers require adequate airflow to operate reliably. The recommended airflow is 200 LFM (linear feet per minute). Forced airflow is recommended. Ambient temperature with forced airflow 0 °C to 55 ° C Ambient temperature with Battery Backup Unit (BBU)1 0 °C to 40 ° C Relative humidity 10% to 90%, noncondensing Altitude Up to 3,000 meters 1 BBU is not supported on all controllers. See page 19 for more information. Note: Ambient temperature is measured 1" from RAID processor. DC Power Requirements Bus Type PCIe PCIe Description Ripple and noise DC Voltage Requirements 50 mV peak-to-peak (max) 3.3 V ± 9%, 12 V ± 8% Current Requirements Adaptec Model Adaptec RAID 5085 Adaptec RAID 5805/5805Q Adaptec RAID 5405 Adaptec RAID 5445 Adaptec RAID 5805Z/5805ZQ Adaptec RAID 5405Z Adaptec RAID 5445Z Adaptec RAID 51245 Adaptec RAID 51645 Adaptec RAID 52445 Adaptec RAID 2045 Adaptec RAID 2405/2405Q Adaptec RAID 2805 Adaptec RAID 6405 Adaptec RAID 6445 Adaptec RAID 6805/6805Q Adaptec RAID 6405E Adaptec RAID 6805E Adaptec RAID 6405T Adaptec RAID 6805T/6805TQ Typical Current 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 0.45A @ 3.3 VDC; 0.94A @ 12.0 VDC 0.45A @ 3.3 VDC; 1.0A @ 12.0 VDC 0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC 0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC 0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC 0.47A @ 3.3 VDC; 1.68A @ 12.0 VDC 0.47A @ 3.3 VDC; 1.72A @ 12.0 VDC 0.47A @ 3.3 VDC; 1.78A @ 12.0 VDC 0.43A @ 3.3 VDC; 0.83A @ 12.0 VDC 0.43A @ 3.3 VDC; 0.83A @ 12.0 VDC 0.5A @ 3.3 VDC; 0.95A @ 12.0 VDC 0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC 0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC 0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC 0.11A @ 3.3 VDC; 0.75A @ 12.0 VDC 0.125A @ 3.3 VDC; 0.80A @ 12.0 VDC 0.125A @ 3.3 VDC; 0.97A @ 12.0 VDC 0.125A @ 3.3 VDC; 0.97A @ 12.0 VDC

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

Appendix G: Technical Specifications
149
Environmental Specifications
Note:
Adaptec RAID controllers require adequate airflow to operate reliably. The recommended
airflow is 200 LFM (linear feet per minute).
Forced airflow is recommended.
Note:
Ambient temperature is measured 1” from RAID processor.
DC Power Requirements
Current Requirements
Ambient temperature with forced airflow
0 °C to 55 °
C
Ambient temperature with Battery Backup Unit (BBU)
1
1
BBU is not supported on all controllers. See
page 19
for more information.
0 °C to 40 °
C
Relative humidity
10% to 90%
,
noncondensing
Altitude
Up to 3,000 meters
Bus Type
Description
Requirements
PCIe
Ripple and noise
50 mV peak-to-peak (max)
PCIe
DC Voltage
3.3 V ± 9%, 12 V ± 8%
Adaptec Model
Typical Current
Adaptec RAID 5085
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5805/5805Q
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5405
0.45A @ 3.3 VDC; 0.94A @ 12.0 VDC
Adaptec RAID 5445
0.45A @ 3.3 VDC; 1.0A @ 12.0 VDC
Adaptec RAID 5805Z/5805ZQ
0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC
Adaptec RAID 5405Z
0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC
Adaptec RAID 5445Z
0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC
Adaptec RAID 51245
0.47A @ 3.3 VDC; 1.68A @ 12.0 VDC
Adaptec RAID 51645
0.47A @ 3.3 VDC; 1.72A @ 12.0 VDC
Adaptec RAID 52445
0.47A @ 3.3 VDC; 1.78A @ 12.0 VDC
Adaptec RAID 2045
0.43A @ 3.3 VDC; 0.83A @ 12.0 VDC
Adaptec RAID 2405/2405Q
0.43A @ 3.3 VDC; 0.83A @ 12.0 VDC
Adaptec RAID 2805
0.5A @ 3.3 VDC; 0.95A @ 12.0 VDC
Adaptec RAID 6405
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC
Adaptec RAID 6445
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC
Adaptec RAID 6805/6805Q
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC
Adaptec RAID 6405E
0.11A @ 3.3 VDC; 0.75A @ 12.0 VDC
Adaptec RAID 6805E
0.125A @ 3.3 VDC; 0.80A @ 12.0 VDC
Adaptec RAID 6405T
0.125A @ 3.3 VDC; 0.97A @ 12.0 VDC
Adaptec RAID 6805T/6805TQ
0.125A @ 3.3 VDC; 0.97A @ 12.0 VDC