Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 135
Redundant Power Supply, Table 5-3, Redundant Power Supply Specifications
UPC - 720591236915
View all Compaq ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
5-4 Compaq ProLiant ML370 Maintenance and Service Guide Redundant Power Supply Table 5-3 Redundant Power Supply Specifications Input specifications Rated input voltage Rated input frequency Rated input current Rated input power BTU/hr Output power Steady state power Maximum peak power Ambient temperature range Operating Shipping Relative Humidity Operating Nonoperating Maximum web bulb temperature 100 to 240 VAC 50 to 60 Hz 8 A (110 V) to 4 A (220 V) 728 W 2490 400 W 445 W 10° to 35° C (50° to 95° F) -30° to 50° C (-22° to 122° F) 8% to 90% 5% to 95% 38.7° C (101.7° F)
5-4
Compaq ProLiant ML370 Maintenance and Service Guide
Redundant Power Supply
Table 5-3
Redundant Power Supply Specifications
Input specifications
Rated input voltage
100 to 240 VAC
Rated input frequency
50 to 60 Hz
Rated input current
8 A (110 V) to 4 A (220 V)
Rated input power
728 W
BTU/hr
2490
Output power
Steady state power
400 W
Maximum peak power
445 W
Ambient temperature range
Operating
10
°
to 35
°
C (50
°
to 95
°
F)
Shipping
-30
°
to 50
°
C (-22
°
to 122
°
F)
Relative Humidity
Operating
8% to 90%
Nonoperating
5% to 95%
Maximum web bulb temperature
38.7
°
C (101.7
°
F)