Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 91
Message, Description, Recommended Action, Check the Disable Code field. Run Array
UPC - 720591236915
View all Compaq ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Diagnostics and Troubleshooting 3-37 Table 3-16 ADU Diagnostic Messages continued Message Description Accelerator status: Excessive ECC errors detected in at least one cache line. As a result, at least one cache line is no longer in use At least one line in the cache is no longer in use due to excessive ECC errors detected during use of the memory associated with that cache line. Accelerator status: Obsolete data detected During reset initialization obsolete data was found in cache. This was due to drives being moved and written to by another controller. Accelerator status: Obsolete data was discarded During reset initialization obsolete data was found in cache and was discarded (not written to drives). Accelerator status: Obsolete data was flushed (written) to drives During reset initialization obsolete data was found in cache. Obsolete data was written to the drives, but newer data may have been overwritten. Accelerator status: Permanently disabled Array Accelerator board has been permanently disabled. It remains disabled until it is reinitialized using the Array Configuration Utility (ACU). Accelerator status: Possible data loss in cache Possible data loss detected during power-up due to all batteries being below sufficient voltage level and no presence of identification signatures on the Array Accelerator board. Accelerator status: Temporarily disabled Array Accelerator board has been temporarily disabled. Accelerator status: Unrecognized status A status returned from the Array Accelerator board that ADU does not recognize. Accelerator status: Valid data found at reset Valid data was found in posted write memory at reinitialization. Data will be flushed to disk. Accelerator status: Warranty alert Catastrophic problem with Array Accelerator board. Refer to other messages on Diagnostics screen for exact meaning of this message. Recommended Action Replacement of cache should be considered. If cache replacement is not done remaining cache lines should continue to operate properly. Normal operations should continue. The controller will either write data to the drives or discard the data completely. Normal operations should continue. If newer data was overwritten, you may need to restore newer data; otherwise, normal operations should continue. Check the Disable Code field. Run Array Configuration Utility (ACU) to reinitialize the Array Accelerator board. There is no way to determine if dirty or bad data was in the cache and is now lost. Check the Disable Code field. Obtain the latest version of ADU. Not an error or data loss condition; no action required Replace the Array Accelerator board. continued