Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 95
Otherwise, run the System Configuration Utility., Operation of Array Accelerator board
UPC - 720591236915
View all Compaq ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Diagnostics and Troubleshooting 3-41 Table 3-16 ADU Diagnostic Messages continued Message Description Error occurred reading RIS copy from SCSI Port x Drive ID x An error occurred while ADU was trying to read the RIS from this drive. FYI: Drive (bay) X is non-Compaq supplied The installed drive was not supplied by Compaq. Identify controller data did not match with NVRAM The identify controller data from the array controller did not match the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. It could also occur if the firmware on the controller has been upgraded and the System Configuration Utility was not run. Identify logical drive data did not match with NVRAM The identify unit data from the array controller did not match with the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. Insufficient adapter resources The adapter does not have sufficient resources to perform operations to the Array Accelerator board. Drive rebuild may be occurring. Less than 75% batteries at sufficient voltage Operation of Array Accelerator board has been disabled due to less than 75% of battery packs being at sufficient voltage level. Less than 75% batteries at sufficient voltage. Battery pack X below reference voltage. Battery pack on Array Accelerator is below required voltage levels. Logical drive X failed due to cache error This logical drive failed due to a catastrophic cache error. Recommended Action If there were multiple errors, this drive may need to be replaced. If problems exist with this drive, replace it with a Compaq drive. Check the identify controller data under the Inspect Utility. If the firmware version field is the only difference between the controller and nonvolatile RAM data, this is not a problem. Otherwise, run the System Configuration Utility. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Operate the system without the Array Accelerator board until the drive rebuild completes. Allow sufficient time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the Array Accelerator board. Allow sufficient time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the Array Accelerator board. Replace the Array Accelerator board and reconfigure using the Array Configuration Utility. continued