Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 99
messages. Run the System Configuration Utility, was replaced in the wrong slot or
UPC - 720591236915
View all Compaq ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Diagnostics and Troubleshooting 3-45 Table 3-16 ADU Diagnostic Messages continued Message Description Warning bit detected A monitor and performance threshold violation may have occurred. Status of a logical drive may not be OK. Write memory error Data could not be written to cache memory. This typically means that parity error was detected while writing data to cache. This could be caused by incomplete connection between cache and controller. This is not a data loss circumstance. Wrong Accelerator This could mean that either the board was replaced in the wrong slot or placed in a system that was previously configured with another board type. Included with this message is a message indicating the type of adapter sensed by ADU and a message indicating the type of adapter last configured nonvolatile RAM. Recommended Action Check the other error messages on the diagnosis screen for an indication of the problem. With power to system turned off, verify that the cache board is fully connected to controller. Check the diagnosis screen for other error messages. Run the System Configuration Utility to update the system configuration.