Compaq ML370 ProLiant ML370 Maintenance and Service Guide - Page 69
Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict - array accelerator battery
UPC - 720591236915
View all Compaq ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
Diagnostics and Troubleshooting 3-15 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1731 - Fixed Disk 1 does not support DMA Mode. None Hard drive error 1740 - Fixed Disk 0 failed Set Block Mode command None Hard drive error 1741 - Fixed Disk 1 failed Set Block Mode command None Hard drive error 1750 - Fixed Disk 0 failed Identify command None Hard drive error 1751 - Fixed Disk 1 failed Identify command None Hard drive error 1760 - Fixed Disk 0 does not support Block Mode None Hard drive error 1761 - Fixed Disk 1 does not support Block Mode None Hard drive error 1764 - Slot x Drive Array Capacity Expansion Process is temporarily disabled (followed by one of the following): Expansion will resume when Array Accelerator has been reattached. Expansion will resume when Array Accelerator has been replaced. Expansion will resume when Array Accelerator RAM allocation is successful. Expansion will resume when Array Accelerator battery reaches full charge. Expansion will resume when automatic data recovery has been completed. *1766 - Slot x Drive Array requires System ROM Upgrade. Run Systems ROMPaq Utility. 1767 - Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict with the Memory Address Range of an Option Card. Check the Memory Address Configuration of installed Option Card(s) or run Options ROMPaq Utility to attempt SMART-2/E Option ROM Reprogramming. Recommended Action Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Reattach or replace Array Accelerator, wait until the Array Accelerator batteries have charged, or for automatic data recovery to complete, as indicated. Run the latest Systems ROMPaq Utility to upgrade the system ROMs. Press F1 to resume. Remove or reconfigure conflicting Option cards, especially any cards that are not recognized by the System Configuration Utility. Try reprogramming the ROM on the SMART-2/E Controller using the latest Options ROMPaq (version 2.29 or higher). continued