3-38 Compaq ProLiant ML370 Maintenance and Service Guide Table 3-16 ADU Diagnostic Messages continued Message Description Adapter/NVRAM ID mismatch Nonvolatile RAM has an ID for a different controller from the one physically present in the slot. Array Accelerator battery pack X not fully charged Battery is not fully charged. Array Accelerator battery pack X below reference voltage (recharging) Board in use by Expand operation Board not attached Configuration signature is zero Configuration signature mismatch Controller communication failure occurred Controller detected. NVRAM configuration not present Controller firmware needs upgrading Controller is located in special "video" slot Battery pack on Array Accelerator is below required voltage levels. Array Accelerator memory is in use by Expand operation. Array controller configured for use with Array Accelerator board, but one is not attached. ADU detected that nonvolatile RAM contains a configuration signature of zero. Old versions of the System Configuration Utility could cause this. Array Accelerator board configured for a different array controller board. Configuration signature on Array Accelerator board does not match the one stored on the array controller board. Controller communication failure occurred. Nonvolatile RAM does not contain a configuration for this controller. Controller firmware is below the latest recommended version. Controller is installed in slot for special video control signals. If controller is used in this slot, LED indicators on front panel may not function properly. Recommended Action Run the System Configuration Utility. If 75% of batteries present are fully charged, Array Accelerator is fully operational. If less than 75% of batteries are fully charged, allow 36 hours to recharge them. Allow enough time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the Array Accelerator board. Operate system without Array Accelerator board until Expand operation completes. Attach Array Accelerator board to array controller. Run the latest version of System Configuration Utility to configure the controller and nonvolatile RAM. To recognize the Array Accelerator board, run the Array Configuration Utility. ADU was unable to successfully issue commands to the controller in this slot. Run the System Configuration Utility to configure the nonvolatile RAM. Run Options ROMPaq to upgrade the controller to the latest firmware revision. Install the controller in a different slot and run the System Configuration Utility to configure the controller and nonvolatile RAM. Then run the Array Configuration Utility to configure controller. continued